| Date |
Text |
| 2010-02-04 11:06:52 | BUILDING PLAN REVIEW |
| | PERMIT: 09060058 |
| | ADD: 401 N DIXIE HWY |
| | CONT: THE WEITZ CO./ CYNDEE ADAMS |
| | TEL: (561)687-4843 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISION REVIEW |
| | ACTION: DENIED |
| | |
| | 1) THE SUBMITTAL FOR A ROLL UP STEEL DOOR CAN NOT BE |
| | REVIEWED SINCE THE ORIGINAL PLAN A4.01 DID NOT |
| | PROVIDETHE +/- PRESSURES ASSOCIATED WITH IT. THE PERMIT |
| | APPLICATION INDICATED UNDER THE DESCRIPTION OF |
| | WORKINDICATED " REMOVAL OF EXISTING GLAZING AND STOPS. |
| | REPLACE WITH HURRICANE IMPACT GLASS AND NEW STOPS". THE |
| | SUN METALS' COMPLIANCE REPORT FROM HTL IS FOR THE |
| | GLAZED OPENINGS ONLY. THE DESIGNER OF RECORD WILL NEED |
| | TO PROVIDE THE WIND DESIGN CRITERIA AND THE ASOCIATED |
| | PRESSURES BEFORE A REVIEW OF THIS PRODUCT CAN TAKE |
| | PLACE. |
| | 1603.1.4 WIND DESIGN DATA. |
| | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| | BUILDING: |
| | 1.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| | (KM/HR). |
| | |
| | 1.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| | |
| | 1.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| | DIRECTION SHALL BE INDICATED. |
| | |
| | 1.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| | |
| | 1.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION |
| | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| | PROFESSIONAL. |
| | |
| | 2) THE LOCATION OF THE GARAGE DOOR IS UNKNOWN, THERE |
| | WERE NO ELEVATIONS SUBMITTED UNDER BASE PERMITTED SET |
| | OF PLANS, THIS OPENING MAY REQUIRE OPENING PROTECTIVES |
| | AS PER SECTION 715 FBC- B & TABLE 715.4 FBC-B. |
| | |
| | 3) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 4) THE REVIEW OF THE ROLL UP DOORS WILL CONSTITUTE A |
| | REVISION TO THE PLANS AND ADDITIONAL REVIEWS WILL OCCUR |
| | A REVISION FEE OF $100.00 BASE FEE AND $50.00 PER PLAN |
| | PAGE |
| | NOT TO EXCEED THE ORIGINAL PERMIT FEE. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |