2009-06-19 14:50:06BUILDING PLAN REVIEW
 PERMIT: 09060020
 ADD: 5601 CORPORATE WAY # 400
 CONT: CLAY KOHLMEYER
 TEL: (561)719-3429
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET A-1 NOTES FOR BUILDING TYPE INDICATES TWO
 BUILDING TYPES A II AND V UNPROTECTED/ UNSPRINKLERED
 PLEASE PROVIDE BUILDING TYPE TABLE 503.
  
 2) SHEET A-1 TENANT DEMISSING WALL EXISTING WALL SYMBOL
 INDICATES TO HAVE FIRE WALL RATING OVER EXISTING WALL
 WITH 2 LAYERS OF TYPE X BOARD ON ONE SIDE, PLEASE
 PROVIDE AN ASSEMBLY NUMBER FOR THIS CONFIGURATION.
 708.3 FIRE-RESISTANCE RATING. FIRE PARTITIONS SHALL
 HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR.
  
 3) PROVIDE TYPE OF FLEXIBLE FIRE PROOFING TO OCCUR AT
 THE ONE-HOURTENANT SEPERATION WALL AT ROOF DECK LEVEL.
 708.4 CONTINUITY. FIRE PARTITIONS SHALL EXTEND FROM THE
 TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW
 TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB
 OR DECK ABOVE OR TO THE FIRE-RESISTANCE-RATED
 FLOOR/CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND SHALL
 BE SECURELY ATTACHED THERETO. IF THE PARTITIONS ARE NOT
 CONTINUOUS TO THE SHEATHING, DECK OR SLAB, AND WHERE
 CONSTRUCTED OF COMBUSTIBLE CONSTRUCTION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved