| 2009-07-30 11:18:02 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW SECOND |
| | CHECKLIST. |
| | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FLORIDA STATUTE. |
| | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK |
| | UP. |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | N1100.0 OF 2007 FLORIDA RESIDENTIAL CODE. (REPEAT |
| | COMMENT. NOT ADDRESSED AT ALL. THIS IS REQUIRED PRIOR |
| | TO RECEIVE THE PERMIT. SEE SEC. N1100.2.2 OF 2007 |
| | FLORIDA RESIDENTIAL CODE). |
| | |
| | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A) PRECAST LINTELS AS SHOWN ON PLANS. (REPEAT COMMENT. |
| | NOT ADDRESSED AT ALL). |
| | |
| | B) ) SIMPSON STRUCTURAL CONNECTORS AS SPECIFIED ON |
| | PLANS AND DETAILS. (REPEAT COMMENT. NOT ADDRESSED AT |
| | ALL). |
| | |
| | 4- SHEET 3.1: |
| | A) REVISE EGRESS WINDOWS NOTE: SEE SEC. R310 OF 2007 |
| | FLORIDA RESIDENTIAL CODE FOR CORRECT MIN. OPENING |
| | HEIGHT AND CORRECT MIN. NET CLEAR OPENING. (REPEAT |
| | COMMENT. NOT PROPERLY ADDRESSED. EGRESS WINDOW OPENING |
| | IS NOT MEASURED BY THE MIN. TOTAL GLASS AREA BUT BY THE |
| | MIN. TOTAL OPENING AREA. ALSO, CLARIFY WHERE IS THE |
| | MIN. CLEAR OPENING HEIGHT OF 31" AND MIN. CLEAR OPENING |
| | WIDTH OF 36" TAKEN FROM. ALSO, THE LAST SENTENCE THAT |
| | "THE NET CLEAR OPENING SHALL IN NO CASE BE LESS THAN 5 |
| | SQ.FT" . IS INCORRECT. THIS OPENING APPLIES TO GROUND |
| | UNITS ONLY. SEE SEC R310 OF 2007 FLORIDA RESIDENTIAL |
| | CODE AND REVISE INFORMATION AS REQUIRED. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |