Plan Review Notes
Plan Review Notes For Permit 09060009
Permit Number 09060009
Review Stop M
Sequence Number 1
Notes
Date Text
2009-06-19 11:03:28REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. PLANS SHOW THE GARAGE BEING CONVERTED TO A BEDROOM.
 ANY EXPANSION OF THE CONDITIONED SPACE IS DEFINED AS AN
 ADDITION PER FBC-R SECTION N1100.7.3. ADDITIONS TO
 EXISTING RESIDENTIAL BUILDINGS SHALL BE CONSIDERED NEW
 BUILDING CONSTRUCTION AND SHALL COMPLY WITH THE
 REQUIREMENTS OF EITHER METHOD A OR B AS APPLICABLE PER
 FBC-R SECTION N1100.0.3. ADDITIONS THAT ARE UNABLE TO
 COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE
 MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE
 BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2.
  
 2. NO MECHANICAL INFORMATION IS PROVIDED ON PLANS.
 PLEASE SHOW HOW EXISTING A/C SYSTEM IS TO BE MODIFIED
 OR WHAT NEW SYSTEM IS BEING INSTALLED FOR THE NEWLY
 CONDITIONED SPACE. AT A MINIMUM, COMPLIANCE WITH
 FBC-R303.8 MUST BE SHOWN ON PLANS.
  
 3. SHOW LOCATION OF DRYER AND BATH EXHAUST TERMINATIONS
 IN ACCORDANCE WITH FBC-R303.4, FBC-R303.5 AND FBC-R
 SECTION M1501.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: