2009-05-22 16:24:23RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009
 REVISIONS.
  
 1- NEED TO PROVIDE SIGNED AND SEALED RAS 117
 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER
 AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON SHEET 20
 OF 20 OF NOA 08-0512.06 SUBMITTED. ASSEMBLY SELECTED ON
 SHEET 19 OF 20 IS GOOD FOR A MAXIMUM DESIGN PRESSURE OF
 -52.5PSF. NEED TO PROVIDE NAIL ENHANCING FOR PERIMETER
 AND CORNER AREAS IN ORDER TO MEET THE DESIGN PRESSURES
 REQUIREMENTS OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL
 CODE.
 ***NOTE: DESIGN PROFESSIONAL DOING THE CALCULATIONS
 NEEDS TO TAKE INTO CONSIDERATION THAT ACCORDING TO THE
 2009 REVISIONS TO THE 2007 FLORIDA RESIDENTIAL CODE,
 THIS BUILDING IS LOCATED ON EXPOSURE "C". SEE SEC. R301
 OF 2009 REVISIONS FOR REVISIONS DONE TO THE EXPOSURE
 CATEGORY.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION WAS UPDATED AS REQUIRED BY SEC. 108.3
 CITY AMENDMENTS TO FBC. OWES $78.17 FOR UPDATED
 VALUATION.
  
 3- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712