2009-05-20 11:50:29RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009
 REVISIONS.
  
 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 ON NOA 07-1203.01
 SUBMITTED.
 ***NOTE: DESIGN PROFESSIONAL DOING THE CALCULATIONS TO
 TAKE INTO CONSIDERATION THE EXPOSURE CATEGORY AS
 REQUIRED BY 2009 REVISIONS TO SEC. R301.2.1.4.3 OF 2004
 FLORIDA RESIDENTIAL CODE. WHAT USED TO BE CONSIDERED
 EXPOSURE B, NOW MAY BE CONSIDERED EXPOSURE C. SEE 2009
 REVISIONS.
  
 2- CLEARLY IDENTIFY ON PRODUCT APPROVAL SUBMITTED WHICH
 APPROVED ASSEMBLY AND FASTENING OPTION IS GOING TO BE
 INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES AND NAIL ENHANCING REQUIREMENTS OF GENERAL
 LIMITATION #7.
  
 3- CLARIFY IF RE-ROOFING ENTIRE ROOF OR ONLY A SMALL
 PART OF THE ROOF. PERMIT APPLICATION CALLS FOR ONLY
 141SF OF ROOF TO BE REPLACED.
  