| 2009-06-05 15:00:17 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST. |
| | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 |
| | REVISIONS. |
| | |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FLORIDA STATUTE. |
| | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK |
| | UP. |
| | |
| | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | N1100.0 OF 2007 FLORIDA RESIDENTIAL CODE. |
| | |
| | 3- PROVIDE COMPLETE SPECIFICATIONS FOR CLOSING OF |
| | EXISTING GARAGE DOOR OPENING. SPECIFY BOTTOM AND TOP |
| | PLATES AND ALL FASTENERS. SPECIFY WALL SHEATHING |
| | FASTENING, ETC. WALL TYPE 3 ON SHEET 3.1 IS MISSING ALL |
| | THIS INFORMATION. |
| | SEC. 106.1.2 CITY AMENDMENTS TO FBC TO VERIFY |
| | COMPLIANCE WITH THE DESIGN LOADS OF SEC. R301 2007 |
| | FLORIDA RESIDENTIAL CODE. |
| | |
| | 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A) WINDOW MULLIONS. AND CLEARLY MARK ON PRODUCT |
| | APPROVAL DRAWINGS SPECIFIC MULLION SIZE AND FASTENERS |
| | TO VERIFY COMPLIANCE WITH THE CALCULATED DESIGN |
| | PRESSURES. |
| | |
| | B) ALL EXTERIOR DOORS AS SHOWN ON PLANS. |
| | |
| | C) STORM SHUTTERS SINCE SINGLE HUNG WINDOWS PRODUCT |
| | APPROVAL NOA 08-0527.15 SUBMITTED DOESN'T HAVE ANY |
| | IMPACT RATING. PROVIDE COMPLETE INSTALLATION SCHEDULE. |
| | SEE ATTACHED SAMPLE. AND, CLEARLY MARK ON SHUTTERS |
| | DRAWINGS SPECIFIC MOUNTING CONDITIONS (EG: WALL |
| | MOUNTED, BUILT OUT, ETC) AND SPECIFIC ANCHOR TO BE USED |
| | ACCORDING TO THE SUBSTRATE TO BE ATTACHED TO (EG: |
| | CONCRETE, CONCRETE BLOCK OR WOOD). |
| | |
| | D) ALUMINUM ROOF PANELS TO BE USED. |
| | |
| | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY |
| | AMENDMENTS TO FBC. |
| | ***NOTE: RUBBER STAMP USED ON WINDOW PRODUCT APPROVAL |
| | IS NOT ACCEPTABLE BECAUSE IT DOENS'T IDENTIFY THE |
| | ENGINER WHO REVIEWED THE PLANS. IT ONLY SAYS THAT |
| | PRODUCT APRPOVAL WAS REVIEWED WITHOUT IDENTIFYING THE |
| | ENGINEER WHO REVIEWED IT. |
| | |
| | 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. REVISE VALUATION TO INCLUDE ALL LABOR AND |
| | MATERIALS. ALSO, INCLUDE ALL PROFESSIONAL FEES AS |
| | REQUIRED BY SEC. R108.3 CITY AMENDMENTS TO FBC. |
| | |
| | 7- ENGINEER OF RECORD TO SIGN AND SEAL SHEET 1.0 AS |
| | REQUIRED BY CHAPTER 471 FLORIDA STATUTE. |
| | |
| | 8- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD |
| | (561)233-5120) TO CHECK IF IMPACT FEES ARE DUE. BRING |
| | BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE |
| | DUE. |
| | ***NOTE: COORDINATE WITH ZONING TO SEE IF PROPOSED |
| | APARTMENT IS ALLOWED. SEE ZONING COMMENTS. |
| | |
| | 9- SHEET 4.0: REVISE BUILDING EXPOSURE. ACCORDING TO |
| | 2009 REVISIONS TO 2007 FLORIDA RESIDENTIAL CODE THIS |
| | BUILDING IS LOCATED ON EXPOSURE "C", NOT "B". REVISE |
| | ALL DESIGN PRESSURES ACCORDINGLY. SEE 2009 REVISIONS TO |
| | SEC. R301 REGARDING BUILDING EXPOSURE. |
| | ***NOTE: CHECK SIZE OF BEAMS SPECIFIED ON PLANS TO |
| | VERIFY COMPLIANCE WITH THE EXPOSURE C DESIGN PRESSURES |
| | AND COLUM SPACING AS REQUIRED BY TABLE 502E OF EXPOSURE |
| | C TABLES FROM THE ALUMINUM ASSOCIATION MANUAL |
| | REFERENCED ON CHAPTER 20 OF FBC 2007. |
| | |
| | 10- SHEET 7.0. CLARIFY WHY DESIGN CRITERIA ON LEFT SIDE |
| | OF SHEET REFERENCES BUILDING EXPOSURE "C", WHILE |
| | ALUMINUM DESIGN CRITERIA ON RIGHT SIDE OF SHEET |
| | REFERENCES BUILDING EXPOSURE "B". REVISE AS REQUIRED TO |
| | MATCH. AND REVISE ALL DESIGN PRESSURES ACCORDINGLY. |
| | COORDINATE WITH ITEM #9 ABOVE. |
| | |
| | 11- COVER PAGE SITE PLAN IDENTIFYIES A PROPERTY ON |
| | BUNKER RD. THIS PROPERTY IS LOCATED ON FRANCIS ST. NO |
| | BUNKER RD. REVISE AS REQUIRED. |
| | |
| | 12- SHEET 3.2: CLARIFY WHY THE WINDOW AND DOOR SCHEDULE |
| | CALL FOR MAX. AND MIN. WIND PRESSURES INSTEAD OF |
| | NEGATIVE AND POSITIVE PRESSURES. |
| | |
| | 13- SHEET 4.1: PROVIDE ENGINEERING ANALYSIS SHOWING WHY |
| | THE WALL HEADER RECEIVING ENTIRE ROOF ON DETAIL 2 IS |
| | ATTACHED TO EXISTING PLYWOOD SHEATHING INSTEAD OF THE |
| | STUDS. SEC. 106.1.2 CITY AMENDMENTS TO FBC. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |