2009-05-20 11:11:02REROOF BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FBC WITH 2009 REVISIONS.
  
 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7. SEE GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA 03-0716.05 SUBMITTED.
 ***NOTE: DESIGN PROFESSIONAL DOING THE RAS 117
 CALCULATIONS TO HAVE INTO CONSIDERATION THE REVISIONS
 TO FBC 2007 SEC. 1609.4.3 REGARDING THE EXPOSURE
 CATEGORIES. SOME EXPOSURE CATEGORIES THAT WERE
 CONSIDERED EXPOSURE B, NOW MAY BE CONSIDERED EXPOSURE
 C. SEE THE 2009 REVISIONS.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION WAS
 UPDATED AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO
 FBC 2004. OWES $123.62 FOR UPDATED VALUATION.
  
 3- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED
 BY SEC. 713.13 FLORIDA STATUTE.
  