| Plan Review Notes For Permit 09050405 |
| Permit Number |
09050405 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-05-20 11:11:02 | REROOF BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7. SEE GENERAL | | | LIMITATION #7 ON LAST PAGE OF NOA 03-0716.05 SUBMITTED. | | | ***NOTE: DESIGN PROFESSIONAL DOING THE RAS 117 | | | CALCULATIONS TO HAVE INTO CONSIDERATION THE REVISIONS | | | TO FBC 2007 SEC. 1609.4.3 REGARDING THE EXPOSURE | | | CATEGORIES. SOME EXPOSURE CATEGORIES THAT WERE | | | CONSIDERED EXPOSURE B, NOW MAY BE CONSIDERED EXPOSURE | | | C. SEE THE 2009 REVISIONS. | | | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION WAS | | | UPDATED AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO | | | FBC 2004. OWES $123.62 FOR UPDATED VALUATION. | | | | | | 3- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED | | | BY SEC. 713.13 FLORIDA STATUTE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|