| Plan Review Notes For Permit 09050341 |
| Permit Number |
09050341 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-06-15 13:15:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. GOVERNING CODE EFFECTIVE MARCH 1, 2009 IS FBC2007 | | | WITH 2009 SUPPLEMENTS. PLEASE REVISE PLAN. | | | | | | 2. FBC2509, PLANS STATE THAT GYPSUM BOARD WILL BE | | | MOISTURE RESISTANT WHERE NEW. SHOWER AND TUB AREAS ARE | | | TO COMPLY WITH FBC2509.2: | | | | | | 2509.2 BASE FOR TILE. CEMENT, FIBER-CEMENT OR GLASS MAT | | | GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1178, C 1288 | | | OR C 1325 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER | | | RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE | | | IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN | | | SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD | | | SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET | | | COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH | | | GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS. | | | | | | |
|