| 2009-07-24 10:27:18 | BUILDING PROVISOS: |
| | |
| | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 2) R703.3 WOOD, HARDBOARD AND WOOD STRUCTURAL PANEL |
| | SIDING. |
| | |
| | R703.3.1 PANEL SIDING. JOINTS IN WOOD, HARDBOARD OR |
| | WOOD STRUCTURAL PANEL SIDING SHALL BE MADE AS FOLLOWS |
| | UNLESS OTHERWISE APPROVED. HORIZONTAL JOINTS IN PANEL |
| | SIDING SHALL BE LAPPED A MINIMUM OF 1 INCH (25 MM) OR |
| | SHALL BE SHIPLAPPED OR SHALL BE FLASHED WITH Z-FLASHING |
| | AND OCCUR OVER SOLID BLOCKING, WOOD OR WOOD STRUCTURAL |
| | PANEL SHEATHING. |
| | |
| | 3) R 806 ROOF VENTILATION |
| | R806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING |
| | AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE |
| | SPACE VENTILATED EXCEPT THAT REDUCTION OF THE TOTAL |
| | AREA TO 1/300 IS PERMITTED, PROVIDED THAT AT LEAST 50 |
| | PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED |
| | VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN |
| | THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT |
| | LEAST 3 FEET (914 MM) ABOVE THE EAVE OR CORNICE VENTS |
| | WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED |
| | BY EAVE OR CORNICE VENTS |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | SURVEY: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |