Plan Review Notes
Plan Review Notes For Permit 09040550
Permit Number 09040550
Review Stop B
Sequence Number 1
Notes
Date Text
2009-04-27 08:58:17RESIDENTIAL (R3) REROOF BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE.
  
 1- DADE COUNTY NOA 07-0111.03 SUBMITTED FOR FLAT ROOF
 ASSEMBLY WAS SUPERSEDED BY DADE COUNTY. SEE ATTACHED
 COPY SHOWING NOA STATUS. PROVIDE CURRENT NOA 07-0730.03
 WHICH IS IS THE ONE WHO SUPERSEDES NOA SUBMITTED.
  
 2- SELECTED APPROVED ASSEMBLY HIGHLIGHTED ON SHEET 18
 OF 19 IS FOR TILE UNDERLAYMENT. NEED TO SELECT APPROVED
 ASSEMBLY FOR FLAT ROOFING NOT TILE UNDERLAYMENT.
  
 3- MARK ON PRODUCT APPROVAL SPECIFIC BASE SHEET
 FASTENING OPTION TO BE INSTALLED.
  
 4- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL
 LIMITATION #7. SEE GENERAL LIMITATION #7 ON LAST PAGE
 OF NOA SUBMITTED.
  
 5- OWES $26.18 FOR UPDATED PERMIT VALUATION AS REQUIRED
 BY SEC. 108.3 CITY AMENDMENTS TO FBC.
  
 6- ROOF WITH 3:12 PITCH REQUIRES 2 LAYERS OF
 UNDERLAYMENT. SEC. R905.2.2 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 7- ROOF SHEATHING TO BE RENAILED AT 4" O.C. IN ROOF
 ZONE 3 AS REQUIRED BY SEC. R803.2.3.1 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712