Plan Review Notes
Plan Review Notes For Permit 09040094
Permit Number 09040094
Review Stop B
Sequence Number 2
Notes
Date Text
2009-06-04 14:01:17MET WITH THE HOMEOWNER AT THE RESIDENCE TO VERIFY CODE
 COMPLIANCE WITH THE 2007 FEBC AND FOR THE REQUESTED
 CHANGE OF OCCUPANCY. THE FOLLOWING WAS OBSERVED:
  
 1) THE CARE INDICATED ON THE PLAN IS FOR 6 ADULTS FOR
 24 HOUR SUPERVISION.
 2) AS PER THE FBC, SECTION 308.2 THE INTENDED OCCUPANCY
 SHALL BE CLASSIFIED AS R-4. THE EXISTING OCCUPANCY IS
 R-3.
 3) AS PER SECTION 912 .4, FEBC, ALL MEANS OF EGRESS
 SHALL COMPLY WITH CHAPTER 10 OF THE FBC. THE BEDROOM ON
 LOCATED ON THE 2ND FLOOR, WEST ELEVATION DOES NOT
 POSSESS AN EMERGENCY ESCAPE/RESCUE OPENING AND,
 THEREFORE,,DOES NOT MEET THE REQUIREMENTS OF THE
 FORMER.
 4) ACCESSIBILITY: ALL BUIDINGS UNDERGOING A CHANGE OF
 OCCUPANCY CLASSIFICATION SHALL COMPLY WITH SECTION
 912.8. THE BATHROOM DOOR SHALL HAVE A 29" CLEARANCE.
 5) FIRE PROTECTION SYSTEMS SHALL BE PROVIDED IN
 ACCORDANCE WITH SECTIONS 912.2.1 AND 912.2.2 OF THE
 FEBC.
 6.) THE EXISTING STAIR HANDRAIL HEIGHT REQUIRES
 ADJUSTMENT AS PER SECTION 912.4.1.