| 2009-04-14 14:24:44 | DENIED |
| | REFERENCE: |
| | FBC-2007 RESIDENTIAL |
| | |
| | A. THE FOLLOWING INFORMATION IS REQUIRED FOR GAS |
| | PERMIT: |
| | |
| | 1. SUBMIT AN ISOMETRIC DRAWING THAT |
| | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE |
| | AND CORRESPONDING LENGTHS PER FBC-2007 |
| | FUEL GAS CODE. THE PIPE SCHEMATIC SUBMITTED IN NOT IN |
| | ISOMETRIC FORM. THE SCHEMATIC INDICATES THAT THE PE |
| | POLY PIPE IS UNDERGROUND AND IF SO THE METER IS ALSO |
| | SHOWN UNDERGROUND. THE RANGE COOKTOP PIPING IS NOT |
| | CLEAR IN HOW IT WILL BE RUN. (SEE EXAMPLE OF ISOMETRIC |
| | DRAWING). |
| | |
| | 2. SHOW THE DISTANCE FROM THE POINT OF |
| | DELIVERY, (METER), TO THE MOST REMOTE |
| | OUTLET IN THE BUILDING AND/OR SYSTEM PER |
| | FBC-2007 FUEL GAS CODE APPENDIX A - USE |
| | OF CAPACITY TABLES A.3.1(4). |
| | |
| | 3. SUBMIT CALCULATIONS FOR COMBUSTION |
| | AIR (IF APPLICABLE) PER FBC-2007 FUEL GAS |
| | CODE SECTION 304. |
| | |
| | 4. INDICATE THE DELIVERY PRESSURE (PSI) |
| | PER FBC-2007 FUEL GAS CODE SEC. 402.2. |
| | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. - THE PLANS SHOW A |
| | 2PSI METER, BUT INDICATES 12" WC AT THE APPLIANCES. IF |
| | THE METER IS 2PSI THEN GAS REGULATORS WILL BE REQUIRED. |
| | PLEASE CLAIFY. |
| | |
| | B. PLANS INDICATE THE WORK SHALL COMPLY WITH NFPA 54. |
| | PLEASE BE ADVISED THAT NFPA 54 WAS NOT ADOPTED BY |
| | FBC-2007 AND THAT THE DESIGN SHALL BE PER FBC-2007 |
| | RESIDENTIAL/2007 FUEL GAS CODE. PLEASE CHANGE |
| | REFERENCE. |
| | |
| | C. THE PERSON RESPONSIBLE FOR THE DRAWINGS SHALL PRINT |
| | THEIR NAME AND PUT THEIR SIGNATURE ON THE PLANS. |
| | SECTION 1-6.1.3. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |