| 2009-04-09 11:39:47 | DENIED |
| | REFERENCE: |
| | FBC-2007 RESIDENTIAL W/2009 SUPPLEMENTS |
| | FBC-2007 EXISTING BUILDING |
| | FBC-2004 CHAPTER 1 WPB AMENDMENTS |
| | |
| | 1. SHT A-1 CODE TABULATION INDICATES THE PLANS WERE |
| | DESIGNED UNDER THE FBC-2004 VERSION. THE CODE ADOPTED |
| | SINCE MARCH 1, 2009 IS THE FBC-2007 W/2009 CODE. PLEASE |
| | CHANGE REFERENCE AND DESIGN TO REFLECT NEW CODE. |
| | |
| | 2. INDICATE THE LEVEL OF ALTERATION PER CHAPTER 4 OF |
| | THE EXISTING BUILDING CODE & SECTION 106.1.1. |
| | |
| | 3. SHTS A-2 & MP INDICATES 1/4" PER FT SCALE. THE |
| | OPENING FOR THE WATER CLOSET SHALL BE A MINIMUM 30 |
| | INCHES PER SECTION P2705.1(5). THE PLANS SCALE OUT LESS |
| | THAN THE REQUIRED 30 INCHES. PLEASE INDICATE THE |
| | OPENING SIZE FOR THE WATER CLOSET AND MAKE SURE THE |
| | OPENING SCALES OUT CORRECTLY. |
| | |
| | 4. SHT MP THE TUB DOWNSTREAM OF THE WATER CLOSET IS NOT |
| | VENTED AS SHOWN. SECTION 901.2.1. A VENT IS REQUIRED |
| | BETWEEN THE W/C AND THE TUB. |
| | |
| | 5. THE PLANS INDICATE THE WASH MACHINE HAS BEEN |
| | RELOCATED. PLEASE INDICATE WITH A SANITARY ISOMETRIC |
| | RISER DIAGRAM HOW THE PIPING TO THE WASH MACHINE WILL |
| | BE RUN AND INDICATE ALL PIPE SIZES. SECTION |
| | 106.3.5.1.3. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |