| Plan Review Notes For Permit 09030575 |
| Permit Number |
09030575 |
|
| Review Stop |
M |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2009-05-20 09:14:04 | MECHANICAL PROVISO: | | | | | | M1305.1.3 APPLIANCES IN ATTICS. ATTICS CONTAINING | | | APPLIANCES REQUIRING ACCESS SHALL BE PROVIDED WITH AN | | | OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO | | | ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY | | | SHALL NOT BE LESS THAN 30 INCHES (762 MM) HIGH AND 22 | | | INCHES (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) | | | IN LENGTH MEASURED ALONG THE CENTERLINE OF THE | | | PASSAGEWAY FROM THE ATTIC ACCESS OPENING TO THE | | | APPLIANCE'S SERVICE PANEL. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING NOT LESS THAN 24 INCHES (610 | | | MM) WIDE. A LEVEL SERVICE SPACE NOT LESS THAN 30 INCHES | | | (762 MM) DEEP AND 30 INCHES (762 MM) WIDE SHALL BE | | | PRESENT AT THE FRONT OR SERVICE SIDE OF THE APPLIANCE. | | | THE CLEAR ACCESS OPENING DIMENSIONS SHALL BE A MINIMUM | | | OF 20 INCHES BY 30 INCHES (508 MM BY 762 MM), WHERE | | | SUCH DIMENSIONS ARE LARGE ENOUGH TO ALLOW REMOVAL OF | | | THE LARGEST APPLIANCE. | | | |
|