| Plan Review Notes For Permit 09030496 |
| Permit Number |
09030496 |
|
| Review Stop |
P |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2009-07-07 13:30:13 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | PDI-WH 201 | | | | | | 1. SHT P-3 NEW PLUMBING NOTES #13. AIR CHAMBERS ARE NOT | | | APPROVED. PDI-WH 201 PLEASE DELETE FROM NOTES. | | | | | | 2. SHT P-4 WATER ISOMETRIC RISER DIAGRAM. THE WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR THE FIXTURES IN | | | AN "EFFECTIVE RANGE" NOT IN THE CEILING AS SHOWN. | | | PDI-WH 201. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|