| Date |
Text |
| 2009-05-15 13:55:51 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | FROM PREVIOUS LIST: |
| | |
| | 1-3. ADDRESSED. |
| | |
| | 4. FOOTINGS WERE ADDED TO THE PLAN BUT ARE 8X8 WITH ONE |
| | #5. THIS IS THE FOOTING TYPICALLY USED FOR ALUMINUM |
| | STRUCTURES; THIS IS HEAVIER THAN AN ALUMINUM STRUCTURE. |
| | PLEASE PROVIDE CALCULATIONS TO SHOW THAT THE FOOTINGS |
| | ARE ADEQUATE FOR THE PROPOSED PATIO. |
| | |
| | 5-14. ADDRESSED. |
| | |
| | 15. A ROOF PERMIT WILL BE REQUIRED. FOR FLAT DECKS, |
| | CONTRACTOR IS TO INDICATE WHICH APPROVED ASSEMBLY WILL |
| | BE USED AND SPECIFY ENHANCED FASTENING FOR CORNER AND |
| | PERIMETER ZONES IF REQUIRED. FLORIDA STATE OR LOCAL |
| | PRODUCT APPROVAL REQUIRED FAC9B72 FOR ROOF COVERING. |
| | |
| | THIS CAN BE A PROVISO ITEM (ROOF PERMIT REQUIRED). |
| | |
| | 16. ADDRESSED. |
| | |
| | 17. THIS PROPERTY RECEIVED A STOP WORK ORDER FOR |
| | ELECTRIC WORK PERFORMED WITHOUT A PERMIT. PLEASE |
| | ADDRESS THIS ISSUE AT THIS TIME OR ADVISE AS TO STATUS |
| | OF THIS ISSUE. |
| | |
| | NEW COMMENTS: |
| | |
| | A. SEE ATTACHED FROM IBHS GUIDELINES FOR HURRICANE |
| | RESISTANT RESIDENTIAL CONSTRUCTION AS AN EXAMPLE |
| | (ALTHOUGH THIS IS FOR SLOPE 5DEGREES, FLAT HAS MORE |
| | STRINGENT REQUIREMENTS). THE FOLLOWING ITEMS DO NOT |
| | COMPLY WITH THE PRESCRIPTIVE DESIGN REQUIREMENTS; |
| | THEREFORE, REQUIRE CALCULATIONS SHOWING THAT THESE |
| | ITEMS MEET MINIMUM CODE REQUIREMENTS: |
| | |
| | COLUMNS (4X4 POSTS, 10' SPAN, 7' SPACING) |
| | |
| | RAFTERS, 2X4 12" SPACING |
| | |
| | BEAM, DOUBLE 2X4 WITH FLITCH |
| | |
| | 8X8 FOOTER (SEE ALSO ITEM 4) |
| | |
| | |
| | |