| Plan Review Notes For Permit 09030377 |
| Permit Number |
09030377 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-03-19 06:56:46 | PROVISO: R703.6.3 WHERE CEMENT PLASTER (STUCCO) IS TO | | | BE APPLIED TO LATH OVER FRAME CONSTRUCTION, MEASURES | | | SHALL BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT | | | PLASTER AND THE WATER-RESISTIVE BARRIER. A BOND BREAK | | | SHALL BE PROVIDED BETWEEN THE WATER-RESISTIVE BARRIER | | | AND THE CEMENT PLASTER (STUCCO) CONSISTING OF ONE OF | | | THE FOLLOWING: | | | 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER | | | MATERIAL; OR | | | 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER | | | OVER AN APPROVED PLASTIC HOUSE WRAP; OR | | | 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN | | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS |
|