| 2009-05-06 16:40:27 | BUILDING PLAN REVIEW |
| | PERMIT: 09030356 |
| | ADD: 2730 S DIXIE HWY |
| | CONT: RUSSELL W CLARK, LLC |
| | TEL: (561)306-3634 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| | BUILDING WITH 2009, 2007 EXISTING BUILDING CODEW/ 2009 |
| | SUPPLEMENTS. PLEASE INDICATE TO WHAT LEVEL OF |
| | ALTERATION IS TO TAKE PLACE OR HAS TAKEN PLACE UNDER |
| | THIS PERMIT. 401.4 A DESIGN PROFESSIONAL OR AN OWNER |
| | MUST ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION |
| | PURSUANT TO SECTIONS 403, 404 AND 405 OF THIS CODE. |
| | |
| | 3) THE PRE-INSPECT INDICATED WORK HAS ALREADY STARTED, |
| | PLEASE INDICATE THE SCOPE OF WORK TO BE REVIEWED UNDER |
| | THIS PERMIT. DEPENDING ON THE SCOPE OF WORK THE DOLLAR |
| | AMOUNT LISTED ON THE PERMIT APPLICATION WILL CHANGE. W |
| | P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. |
| | ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, |
| | AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, |
| | A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| | ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| | APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 4) PLEASE PROVIDE THE FOLLOWING INFORMATION TO |
| | DETERMINE THE MINIMUM BASE BUILDING REQUIREMENTS (TABLE |
| | 503/ 601. 110.2* W. P. B. ADMINISTRATIVE |
| | CODE, INFORMATION THAT IS REQUIRED FOR RECORD KEEPING & |
| | FOR CERTIFICATE OF OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS |
| | DESIGNED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN TABLE 503/ |
| | CHAPTER 6, TABLE 601. |
| | D) THE OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED |
| | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | .H ) NUMBER OF FLOORS/ OCCUPANCY SEPERATION? |
| | I ) SQ. FT. FOOTPRINT |
| | |
| | 5) PLEASE PROVIDE A LIFE SAFET PLAN INDICATING EXIT |
| | ROUTES WITH TABLES AND CHAIRS. 106.3.5(6). |
| | |
| | 6) PROVIDE A PLAN WITH ACCESSIBLE SEATING. 11-5.1 |
| | GENERAL. EXCEPT AS SPECIFIED OR MODIFIED IN THIS |
| | SECTION, RESTAURANTS AND CAFETERIAS SHALL COMPLY WITH |
| | THE REQUIREMENTS OF SECTION 11-4.1 TO SECTION 11-4.35. |
| | WHERE FIXED TABLES (OR DINING COUNTERS WHERE FOOD IS |
| | CONSUMED BUT THERE IS NO SERVICE) ARE PROVIDED, AT |
| | LEAST 5 PERCENT, BUT NOT LESS THAN ONE, OF THE FIXED |
| | TABLES (OR A PORTION OF THE DINING COUNTER) SHALL BE |
| | ACCESSIBLE AND SHALL COMPLY WITH SECTION 11-4.32 AS |
| | REQUIRED IN SECTION 11-4.1.3(18). |
| | |
| | 7) PLANS FAIL TO IDENTY ANY FLOOR, WALL OR CEILING |
| | FINISHES, PLEASE PROVIDE IN COMPLIANCE WITH 803.1 |
| | GENERAL. INTERIOR WALL AND CEILING FINISHES SHALL BE |
| | CLASSIFIED IN ACCORDANCE WITH ASTM E 84. SUCH INTERIOR |
| | FINISH MATERIALS SHALL BE GROUPED IN THE FOLLOWING |
| | CLASSES IN ACCORDANCE WITH THEIR FLAME SPREAD AND |
| | SMOKE-DEVELOPED INDEXES. |
| | |
| | CLASS A: FLAME SPREAD 0-25; SMOKE-DEVELOPED 0-450. |
| | |
| | CLASS B: FLAME SPREAD 26-75; SMOKE-DEVELOPED 0-450. |
| | |
| | CLASS C: FLAME SPREAD 76-200; SMOKE-DEVELOPED 0-450. |
| | |
| | EXCEPTION: MATERIALS, OTHER THAN TEXTILES, TESTED IN |
| | ACCORDANCE WITH SECTION 803.2. |
| | |
| | 8) PLANS INDICATE WITHIN TITLEBLOCK DOUG MCINTEE DESIGN |
| | GROUP IS INVOLVED WITH THIS PROJECT, BEING COMMERCIAL |
| | THE DESIGN GROUP CAN NOT WORK IN THE COMMERCIAL MARKET. |
| | FL |
| | S S 481.229(6)(A). |
| | |
| | 9) PLEASE PROVIDE WHO IS THE ARCHITECT OF RECORD, PLANS |
| | HAVE A RAISED SEAL OF THE CORPORATE SEAL NOT THE |
| | DESIGNER OF RECORD. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.FL ADMIN |
| | CODE 61G16.003 ARCHITECTS |
| | 61G1-16.004 FL. ADMIN. CODE. PLANS PREPARED BY A |
| | REGISTERED ARCHITECT SHALL INCLUDE A TITLE BLOCK WHICH |
| | MUST: |
| | - STATE THE FIRM NAME, ADDRESS AND TELEPHONE NUMBER |
| | - STATE THE FIRM LICENSE NUMBER |
| | - STATE PROJECT NAME OR IDENTIFICATION |
| | - STATE DATE PREPARED |
| | - INCLUDE AN ORIGINAL SIGNATURE AND DATED SEALED |
| | INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING THE |
| | PLANS |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |