| Date |
Text |
| 2009-04-02 14:37:02 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. CONSTRUCTION DOCUMENTS ARE TO BE DIMENSIONED, TO |
| | SCALE, AND SHOW ALL STRUCTURAL DETAILS FBC*106.1.1. FOR |
| | INSTANCE, INCOMPLETE ANCHOR INFORMATION (NO LENGTH |
| | SPECIFIED FOR LAGS). FOR INSTANCE, ON ONE SHEET A 4X6 |
| | IS NOTED, BUT DRAWN AS A SQUARE; ORIENTATION CANNOT BE |
| | DETERMINED. ANOTHER EXAMPLE IS THE CANTALEVER SHOWN ON |
| | ONE OF THE DETAILS; NO DIMENSION FOR CANTALEVER SHOWN. |
| | PLEASE PROVIDE STRUCTURAL DRAWINGS INCLUDING |
| | ELEVATIONS, FLOOR PLAN, AND A SECTION IF NECESSARY IN |
| | ORDER TO SHOW NATURE OF PROPOSED WORK. IF NECESSARY, |
| | PROVIDE DETAILS WITH DETAIL MARKERS WHICH CORRELATE |
| | WITH THE FLOOR PLAN. |
| | |
| | 2. DECLARE GOVERNING CODE AND WIND DESIGN CRITERIA FBC |
| | R 301. |
| | |
| | 3. PROVIDE ALL DIMENSIONS; DISTANCE BETWEEN POSTS, |
| | STRUCTURE HEIGHT, ETC. NOT PROVIDED. |
| | |
| | 4. SEVERAL PAGES WERE SUBMITTED BUT NOTHING TO IDENTIFY |
| | THE SHEETS (SUCH AS PAGE NUMBERS OR LABELS). FOR |
| | INSTANCE, A SHEET WAS PROVIDED SHOWING A 4X4 DIAGONAL |
| | SUPPORT. THIS IS NOT SHOWN ON OTHER SHEETS. |
| | |