| Plan Review Notes For Permit 09030178 |
| Permit Number |
09030178 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2009-03-18 14:40:49 | RESIDENTIAL (R3) SOLAR PANELS, BUILDING REVIEW SECOND | | | CHECKLIST. | | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2008 | | | REVISIONS. | | | | | | 1- AS OF MARCH 1ST 2009 THE CODE IN EFFECT IS THE 2007 | | | FBC WITH THE 2008 REVISIONS. ENGINEER'S WIND LOAD | | | DESIGN CRITERIA ON SHEET 3 OF 3 SUBMITTED THE FIRST | | | TIME SPECIFIED THE ASCE 7-05 AS THE REFERENCE FOR THE | | | DESIGN. THIS IS THE CORRECT ASCE 7 EDITION TO BE USED | | | UNDER THE 2007 FBC. CALCULATIONS SUBMITTED NOW ARE DONE | | | BASED ON THE ASCE 7-02. NEED TO REVISE CALCULATIONS | | | USING THE ASCE 7-05 EDITION. | | | | | | 2- CALCULATIONS SUBMITTED ARE USING "TOWN OF PALM | | | BEACH" TABLE FOR WALL COMPONENTS AND CLADDING. THIS | | | TABLE IS NOT ADOPTED BY THE CITY OF WEST PALM BEACH. | | | THEREFORE IT CAN'T BE USED. ON THE OTHER HAND, DESIGN | | | CRITERIA SHALL BE DONE USING THE ASCE 7-05 TABLES | | | WITHOUT MIXING AND MATCHING OTHER TABLES. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|