| Date |
Text |
| 2009-04-02 17:27:23 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. PROVIDE DIMENSIONS OF PROPOSED SHED TO PROPERTY |
| | LINES, FBC601. |
| | |
| | 2. DECLARE OCCUPANCY CLASSIFICATION, FBC CHAPTER 3. THE |
| | SHED PLANS DECLARE THIS STRUCTURE AS RESIDENTIAL LAWN |
| | STORAGE; THIS DOES NOT APPEAR TO BE APPLICABLE FOR THIS |
| | PROJECT. |
| | |
| | 3. DECLARE OCCUPANT LOAD, FBC CHAPTER 10. |
| | |
| | 4. PLANS SHOW THIS AS ONE PARCEL; PAPA SHOWS THIS AS |
| | THREE SEPARATE PARCELS. IF THIS IS THE CASE, EACH |
| | PARCEL SHOULD HAVE A SEPARATE PERMIT (OTHERWISE, PLEASE |
| | PROVIDE EVIDENCE THAT THESE THREE PARCELS HAVE BEEN |
| | COMBINED INTO ONE PARCEL). PLEASE SEE COMMENT 1; THIS |
| | WOULD BE APPLICABLE TO THE PROPERTY LINE OF THE PARCEL |
| | ON WHICH THE SHED WILL BE LOCATED, NOT THE ADJACENT |
| | PARCEL INCLUDED IN THIS PROJECT. |
| | |
| | 5. PROVIDE A DETAIL FOR THE PROPOSED WALL. |
| | |
| | 6. SHOW ACCESSIBLE ROUTE AS DESCRIBED IN |
| | FBC11-4.1.2(1), INCLUDING ACCESSIBILITY AT THE BUILDING |
| | ENTRANCE. |
| | |
| | 7. SEE COMMENT 4. FBC1002, SEE DEFINITION OF EXIT AND |
| | PUBLIC WAY. IT APPEARS THAT NO EXITING TO THE PUBLIC |
| | WAY IS PROVIDED FROM THE PROPOSED STRUCTURE WITHOUT |
| | CROSSING OVER OTHER PARCELS. PLEASE ADDRESS. |
| | |
| | |
| | |
| | |