| Notes |
| Date |
Text |
| 2009-02-26 14:19:45 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 | | | REVISIONS. | | | | | | 1- PERMIT APPLICATION CALLS FOR REPLACEMENT OF JALOUSIE | | | WINDOWS WITH "IMPACT" FRENCH DOORS WITH SIDELITES. | | | PRODUCT APPROVAL NOA 06-0629.01 SUBMITTED IS FOR | | | "NON-IMPACT" DOORS. PROVIDE PRODUCT APPROVAL FOR IMPACT | | | DOORS AS SPECIFIED ON PERMIT APPLICATION. | | | | | | 2- PROVIDE DETAIL/SPECIFICATIONS SHOWING HOW INSTALLING | | | THE BUCKS AND HEADER TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301 OF 2004 FLORIDA | | | RESIDENTIAL CODE. PERMIT APPLICATION SAYS "INSTALL | | | BUCKS AND HEADER TO COMPLY W/ CODE". THIS DOESN'T | | | PROVIDE ANY INFORMATION ON PROPOSED INSTALLATION. | | | NOTE: CLARIFY WHY INSTALLING NEW HEADER IF DOORS ARE | | | GOING TO BE INSTALLED ON EXISTING OPENING. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|