| 2009-04-10 10:16:04 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | COMMENTS FROM PREVIOUS LIST: |
| | |
| | 1. THE COVER SHEET FOR THE PRODUCT APPROVAL FOR |
| | HURRICANE PANELS WAS PROVIDED. THE EVALUATION REPORT, |
| | INSTALLATION INSTRUCTIONS, AND INSTALLATION SCHEDULE |
| | FORM ARE REQUIRED. THE INSTALLATION SCHEDULE FORM IS |
| | AVAILABLE IN THE LOBBY OR ON THE INTERNET AT HTTP://WWW |
| | .CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLAT |
| | ION.PDF. |
| | |
| | THIS PERMIT CAN BE ISSUED WITH THE PROVISO THAT |
| | SHUTTERS ARE REQUIRED AS A SEPARATE PERMIT. |
| | |
| | 2-4. ADDRESSED. |
| | |
| | 5. A SGD IS SHOWN AS "INFILL" ON AN ELEVATION, ANOTHER |
| | ELEVATION SHOWS A WALL WITH A WINDOW, BUT THE WALL |
| | DETAIL DOESN'T SHOW A WINDOW. THE DETAIL DOES NOT MATCH |
| | THE SCOPE OF WORK. |
| | |
| | 2ND REVIEW, NOT ADDRESSED. PROVIDE STRUCTURAL DETAILS |
| | FOR THE WALLS TO BE BUILT WHICH SHOW THE STRUCTURAL |
| | DETAIL FOR FRAMING TO SUPPORT THE WINDOW AND SLIDING |
| | GLASS DOOR. |
| | |
| | 7. SHOW FINISHED FLOOR IN RELATION TO THE GRADE FBC |
| | R404.1.6. |
| | |
| | 2ND REVIEW, THIS WAS ADDED BUT NOW THE DETAIL DOES NOT |
| | COMPLY WITH FBC R403.1.4. PLEASE REVISE THE DETAIL. |
| | |
| | 8. ADDRESSED. |
| | |
| | 9. SEE ITEM 1. |
| | |
| | 10. BOND BREAK REQUIRED, FBC703.6.3.1. |
| | |
| | A NOTE WAS ADDED STATING BOND BREAK REQUIRED BUT THE |
| | DETAIL SHOWING WALL CONSTRUCTION DOES NOT COMPLY WITH |
| | FBC703.6.3.1. IT IS UNCLEAR WHAT THE NOTE MEANS AS THE |
| | SPECIFICATION FOR CONSTRUCTION DOES NOT COMPLY WITH THE |
| | CODE SECTION OR THE NOTE. PLEASE REVISE. |
| | |
| | 11. SHOW COMPLIANCE WITH FBC704, INSPECTION FOR |
| | TERMITES. |
| | |
| | A NOTE WAS ADDED, BUT THE DETAIL FOR CONSTRUCTION DOES |
| | NOT COMPLY WITH THIS SECTION. IT IS UNCLEAR WHAT THE |
| | NOTE CONTRACTOR TO PROVIDE PROOF OF TERMITE PROTECTION |
| | MEANS OR HOW IT SHOWS COMPLIANCE WITH THIS SECTION. |
| | PLEASE REVISE. |
| | |
| | A SET HAS BEEN RETAINED. WHEN RESUBMITTING, PLEASE |
| | SUBMIT TWO SETS. |
| | |
| | NEW COMMENT: |
| | |
| | FS553.80(2)(B) A 4X PLAN REVIEW FEE WILL BE ASSESSED |
| | WITH COMMENTS ARE NOT ADDRESSED A THIRD TIME. |
| | |
| | |