| Date |
Text |
| 2009-04-30 09:42:52 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STA |
| | |
| | 1-4. ADDRESSED. |
| | |
| | 4. SHOW COMPLIANCE WITH FBC R704, INSPECTION FOR |
| | TERMITES. |
| | |
| | 2ND REVIEW, DETAILS SHOW STUCCO EXTENDING TO GRADE. |
| | PLEASE SEE FBC R704 AND REVISE DETAIL ACCORDINGLY. |
| | |
| | 5-6. ADDRESSED. |
| | |
| | 7. ROOF PERMIT HAS BEEN APPLIED FOR. THEREFORE, ALL |
| | ROOF PERMIT INFORMATION REQUIRED AT THIS TIME: |
| | |
| | A. ADDRESSED. |
| | |
| | B. PROVIDE ENHANCED FASTENING PATTERN FOR PERIMETER AND |
| | CORNER ZONES |
| | |
| | 2ND REVIEW, PLAN WAS REVISED TO STATE "FASTEN TO ALL |
| | SUPPORTS W/8D NAILS @ 6"EDGES, 6" FIELD." IT APPEARS |
| | THAT THIS IS INTENDED TO BE PLYWOOD SHEATHING |
| | FASTENING, BUT THIS DOES NOT COMPLY WITH FBC R |
| | 803.2.3.1 ZONE 3. ADDITIONALLY, THIS DOES NOT ADDRESS |
| | THE COMMENT FOR THE ROOF. PLEASE SEE NOA, GENERAL |
| | LIMITATION #7 ON PAGE 19, ENHANCED FASTENING TO BE IN |
| | ACCORDANCE WITH RAS117 (ALSO NOTE THAT THERE ARE TWO |
| | DIFFERENT FASTENING OPTIONS; ENHANCED FASTENING SHOULD |
| | REFER TO WHICH OPTION IS PROPOSED IN ORDER TO DETERMINE |
| | CODE COMPLIANCE UNLESS THE PATTERN PROPOSED COMPLIES |
| | WITH BOTH). PLEASE NOTE THAT IF ALL REQUIRED |
| | INFORMATION IS NOT PROVIDED PRIOR TO ISSUANCE OF THE |
| | MASTER PERMIT, THE ROOF PERMIT WILL BE VOIDED AND A |
| | SEPARATE PERMIT WILL BE REQUIRED IN ORDER TO AVOID |
| | DELAYS ON THE MASTER PERMIT. |
| | |
| | 8. ADDRESSED. |
| | |
| | 9. FBC R403.1.4, SHOW DISTANCE OF BOTTOM OF FOOTING TO |
| | GRADE. |
| | |
| | 2ND REVIEW, THIS IS SHOWN AS 10IN. SEE FBC R403.1.4, |
| | MINIMUM DEPTH REQUIRED IS 12IN. |
| | |
| | 10-11. ADDRESSED. |
| | |
| | 12. ROOF SHEATHING NAILING NOT COMPLIANT WITH FBC R |
| | 803.2.3.1. SEE DETAILS 1 A3, 2 A3, CHECK ALL. |
| | |
| | 2ND REVIEW, 4IN REQUIRED AT ZONE 3, SEE FBC R803.2.3.1. |
| | |
| | 13-14. ADDRESSED. |
| | |
| | 15. IMPACT FEES MAY BE DUE. PLEASE CONTACT PALM BEACH |
| | COUNTY, 233-5025. |
| | |
| | 2ND REVIEW, THE PLANS MUST BE STAMPED AND THE RECEIPT |
| | (IF FEES ARE DUE) ATTACHED TO THE APPLICATION. THIS MAY |
| | BE DONE AFTER ALL PLAN REVIEWS ARE COMPLETED BUT MUST |
| | BE DONE PRIOR TO PERMIT ISSUANCE. |
| | |
| | 16-17. ADDRESSED. |
| | |
| | |