2009-02-19 09:01:21FAILED
  
 1) THE PCN LISTED FOR THIS PROPERTY IS INCORRECT
 (PARKING GARAGE). ADDITIONALLY, PLEASE VERIFY THE
 ADDRESS AS THE RENDERING SHOWS THE FACADE OF 701 S.
 ROSEMARY.
  
 2) THE CITYPLACE MASTER SIGN PLAN DESIGNATES THE
 ALLOWED SIGN AREA AS CENTERED ABOVE THE ARCH ON THIS
 FA??ADE. THE RENDERING SHOWS THE SIGN CENTERED ON THE
 COLUMN.
  
 3) THE RENDERING SHOWS THE SIGN AS 3' TALL WHILE THE
 DETAIL SHOWS THE SIGN AT 3' 1 5/8 INCHES TALL. THESE
 SHALL SHOW THE SAME CONDITION.
  
 4) THE CITYPLACE MASTER SIGN PLAN LIMITS SIGN TEXT TO A
 MAXIMUM OF 12 INCHES IN HEIGHT. THE PROPOSED
 "FRANCESCA'S" TEXT HEIGHT IS SHOWN AS 23 1/2 INCHES.
  
 5) THE CITYPLACE MASTER SIGN PLAN REQUIRES SIGN TEXT TO
 BE A MINIMUM OF 8 INCHES IN HEIGHT. THE PROPOSED
 "COLLECTIONS" TEXT HEIGHT IS SHOWN AS 8 INCHES.
  
 6) PROVIDE THE LOCATION OF THE BLADE SIGN. NOTE: THE
 CITYPLACE MASTER SIGN PLAN REQUIRES THAT BLADE SIGNS
 SHALL NOT BE WITHIN 6 INCHES OF A NEUTRAL PIER. PLEASE
 SHOW THE DIMENSION TO VERIFY THIS ON THE PLANS.
  
 7) THE CITYPLACE MASTER SIGN PLAN LIMITS THE SIZE OF
 THE BLADE SIGN PANEL TO 18" X 18". THE PROPOSED SIGN IS
 12" X 20".
  
 8) THE MOUNTING DETAILS FOR THE BLADE SIGN BRACKET ARE
 REQUIRED.
  
 9) THE CITYPLACE SIGN PLAN ALLOWS CITYPLACE TO GRANT
 VARIANCES FROM LOCATION PROVISION OF 2 ABOVE AND THE
 DIMENSIONAL PROVISIONS OF 4 THROUGH 7 ABOVE. PROVIDE A
 NOTARIZED LETTER FROM CITYPLACE THAT THEY HAVE GRANTED
 THE SPECIFIC VARIANCES FOR THE PROPOSED SIGNS.
  
 A COPY OF THESE COMMENTS HAS BEEN SENT TO CARLOS BERNAL
 AT CITYPLACE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.
  