| Date |
Text |
| 2009-06-01 09:32:51 | BUILDING PLAN REVIEW |
| | PERMIT: 09020255 |
| | ADD: 1750 FLORIDA MANGO RD |
| | CONT: CARRICK CONSTRUCTION |
| | TEL: (954)415-5705 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | MONDAY, JUNE 01-2009 |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | 1-2 ) COMPLIED |
| | 3A-C) SEMI-COMPLIED, THE SHEET SUPPLIED FROM EEI, |
| | ENGINEERED ENDEVORS INCORPORATED DOES INDICATE THE NEW |
| | SECTION OF TOWER AND BOLTING TO THE EXISTING TOWER |
| | STRUCTURE. |
| | |
| | 3D) NEW COMMENT DEALS WITH THE ENGINEERS SEAL WITH THE |
| | WORDING " CERTIFIED". FBC* 106.1 THE NEW TYPE OF |
| | ENGINEER'S SEAL IS REQUIRED FOR ALL PLANS SEALED AFTER |
| | 12/31/05. ENGINEER'S SEALS INCLUDING THE WORD |
| | "CERTIFICATE" ARE NO LONGER VALID. ON 2/5/04 THE |
| | FLORIDA BOARD OF PROFESSIONAL ENGINEERS AMENDED THE |
| | 'SEALS' RULE AND REQUIRED THAT ALL MEMBERS OBTAIN SEALS |
| | WITH THE WORD "LICENSE" INSTEAD OF "CERTIFICATE". THE |
| | EXTENDED GRACE PERIOD FOR COMPLIANCE ENDED ON 12/31/05. |
| | (REF: 471.025 F.S. AND RULE 61G15-23.001 F.A.C.) |
| | |
| | 3E) EEI IS ALSO MISSING THERE CERTIFICATE OF |
| | AUTHORIZATION: FBC* 106.1 THE NEW TYPE OF ENGINEER'S |
| | SEAL IS REQUIRED FOR ALL PLANS SEALED AFTER 12/31/05. |
| | ENGINEER'S SEALS INCLUDING THE WORD "CERTIFICATE" ARE |
| | NO LONGER VALID. ON 2/5/04 THE FLORIDA BOARD OF |
| | PROFESSIONAL ENGINEERS AMENDED THE 'SEALS' RULE AND |
| | REQUIRED THAT ALL MEMBERS OBTAIN SEALS WITH THE WORD |
| | "LICENSE" INSTEAD OF "CERTIFICATE". THE EXTENDED GRACE |
| | PERIOD FOR COMPLIANCE ENDED ON 12/31/05. (REF: 471.025 |
| | F.S. AND RULE 61G15-23.001 F.A.C.) |
| | |
| | 4) 2ND REQUEST, IETS COVER-SHEET; |
| | 4A) THE REPORT HAS PHOTOCOPIED SIGNATURES, NOT |
| | ORIGINALS, FL ADMINISTRATIVE CODE: 61G15-23.002(2) FL. |
| | ADMIN. CODE. PLANS SIGNED & SEALED BY A PROFESSIONAL |
| | ENGINEER. |
| | (471.025 F.S. AND 471.023 F.S.). |
| | |
| | 4B) 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR |
| | INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED |
| | AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF |
| | THE PRODUCTION & PREPARATION OF EACH SECTION OF THE |
| | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION |
| | ON THE COVER SHEET OR INDEX. |
| | |
| | 4C) 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE |
| | TITLE BLOCK FOR ANY SHEET BEARING THE NAME OF AN |
| | ENGINEER PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING |
| | SERVICES, SHALL INCLUDE THE CERTIFICATE OF |
| | AUTHORIZATION NUMBER. ADD THE NUMBER TO EACH SHEET. |
| | THIS MAY BE ADDED BY HAND. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |