| 2009-03-09 16:58:22 | BUILDING PLAN REVIEW |
| | PERMIT: 09020255 |
| | ADD: 1750 FLORIDA MANGO RD |
| | CONT: CARRICK CONSTRUCTION |
| | TEL: (954)415-5705 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, |
| | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR |
| | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL |
| | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A |
| | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN |
| | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED |
| | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS |
| | WEST PALM BEACH ADMINISTRATIVE CODE. |
| | |
| | 1C) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, |
| | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: |
| | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS |
| | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & |
| | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 1D) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST |
| | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO |
| | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS, PLEASE |
| | UPDATE PLANS SHEET 6 OF 8 AND SHEET# 1 OF STRUCTURAL |
| | CALCULATIONS. |
| | |
| | 2) FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF |
| | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN |
| | "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE |
| | REQUIRED. PLEASE PROVIDE AT WHAT ELEVATION THE SLAB |
| | WILL BE SET, THE FLOODZONE A9- MINIMUM ELEVATION 13.5 |
| | FT. |
| | |
| | 3A) 106.1.2 ADDITIONAL INFORMATION REQUIRED IETS |
| | STRUCTURAL REPORT INDICATES ON SHEET E-1 WHAT APPEARS |
| | TO BE THE TOP CONNECTION (SECTION) OF TOWER. THIS |
| | SECTION IS LOCATED AT HEIGHT 108.8' AND CONTINUES |
| | THROUGH TO 128.8'. THE PERMIT APPLICATION INDICATES |
| | ONLY A TEN FOOT SECTION IS BEING ADDED FROM 113' TO |
| | 123'. PLEASE EXPLAIN THE DIFFERENCE. |
| | |
| | 3B) THE IETS CALCULATIONS DO NOT INDICATE HOW THE TOP |
| | SECTION OF TOWER WILL BE ATTACHED NOR IS THERE ANY |
| | INFORMATION AS TO THE CONFIGURATION, TYPE OF MATERIAL |
| | NOR THICKNESS OF MATERIAL THIS NEW TOWER SECTION WILL |
| | BE CONSTRUCTED FROM, 106.1.2 ADDITIONAL INFORMATION/ |
| | 1609.6.2.1 MAIN WINDFORCE-RESISTING SYSTEM. |
| | |
| | 3C) PLEASE PROVIDE ADDITIONAL INFORMATION ON THE TYPE |
| | OF CONNECTION THE NEW SECTION OF THE TOWER WILL CONSIST |
| | OF, 106.1.2 ADDITIONAL INFORMATION. PLEASE ALSO PROVIDE |
| | WHERE THIS ANYLISS WOULD BE FOUND WITHIN YOUR DOCUMENT? |
| | 106.1.2 ADDITIONAL INFORMATION/ 1609.6.2.1 MAIN |
| | WINDFORCE-RESISTING SYSTEM. |
| | |
| | 4) IETS COVER-SHEET; |
| | 4A) THE REPORT HAS PHOTOCOPIED SIGNATURES, NOT |
| | ORIGINALS, FL ADMINISTRATIVE CODE: 61G15-23.002(2) FL. |
| | ADMIN. CODE. PLANS SIGNED & SEALED BY A PROFESSIONAL |
| | ENGINEER. |
| | (471.025 F.S. AND 471.023 F.S.). |
| | |
| | 4B) 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR |
| | INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED |
| | AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF |
| | THE PRODUCTION & PREPARATION OF EACH SECTION OF THE |
| | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION |
| | ON THE COVER SHEET OR INDEX. |
| | |
| | 4C) 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE |
| | TITLE BLOCK FOR ANY SHEET BEARING THE NAME OF AN |
| | ENGINEER PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING |
| | SERVICES, SHALL INCLUDE THE CERTIFICATE OF |
| | AUTHORIZATION NUMBER. ADD THE NUMBER TO EACH SHEET. |
| | THIS MAY BE ADDED BY HAND. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |