| Notes |
| Date |
Text |
| 2009-04-08 12:44:30 | PROVISO; | | | PROVIDE ROOF SYSTEM AS STATED ON SHEET A3; ROOF PRODUCT | | | APPROVAL FL# 10264-RO(PAGE 2 OF 9); ROOFING MEMBRAINE: | | | FIRESTONE ULTRAPLY TPO 60 MIL: FIRESTONE ISO 95 T GL | | | INSULATION 3.5" TOTAL THICKNESS: R-VALUE 21.7; | | | PROTECTION BOARD DENS-DECK PRIME 1/2" MIN: SYSTEM TYPE | | | C SYSTEM NO. SC-4(ZONE 1&2) SC-7(ZONE 3): MAXIMUM | | | DESIGN PRESSURE SC-4 (-75.0 PSF) SC-7 (-105 PSF). THIS | | | INFORMATION SHALL BE SUBMITTED BY THE ROOFING | | | CONTRACTOR PRIOR TO INSTALLATION. ALSO SUBMIT A LAYOUT | | | OF THEROOF INSULATION PRIOR TO INSTALLATION. | | | | | | PROVIDE ADDITIONAL INFORMATION/ SIGN AND SEAL DOCUMENTS | | | FROM A FLORIDA DESIGN PROFESSIONAL SHOWING HOW THE ROOF | | | TOP UNITS WILL REMAIN IN PLACE DURING PERIODS OF HIGH | | | WINDS. |
|