| Notes |
| Date |
Text |
| 2009-02-10 09:56:15 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ALTERATION | | | | | | DENIED BY BUILDING | | | | | | 1) BECAUSE THE SCOPE OF WORK INCLUDES THE ELIMINATION | | | OR ADDITION OF A DOOR, THIS IS CONSIDERED A LEVEL 2 | | | ALTERATION. PLEASE CHANGE NOTE ON SHEET 1. SEE FBC | | | EXISTING BUILDING SECTION 304. | | | | | | 2) SPECIFY HOW THE EXISTING 2 X 6 WOOD BEAM WILL BE | | | ANCHORED TO THE NEW MASONRY BOND BEAM. FBC EXISTING | | | BUILDING 607.3 AND FBC R301.1 | | | | | | 3) PLEASE SPECIFY ON THE PLANS THAT THIS PORCH IS NOT | | | TO BE CONDITIONED SPACE OR SUBMIT ENERGY CALCULATIONS | | | AND SPECIFY THE EXTERIOR ENVELOPE INSULATION ON THE | | | PLANS. FBC SUBCHAPTER 13-6. | | | | | | 4) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|