| Date |
Text |
| 2009-02-26 15:16:23 | DENIED |
| | REFERENCE: |
| | FBC-2004 RESIDENTIAL CODE |
| | FBC-2004 CHAPTER 1 |
| | |
| | 1. THE PLANS SHOW DETAILS THAT ARE NOT CLEAR OR |
| | LEGIBLE. (SEE VENT DETAIL, MAIN DRAIN DETAIL, |
| | ATMOSPHERIC VENT DETAIL ETC). SECTION 106.1.1 |
| | CONSTRUCTION DOCUMENTS. |
| | |
| | 2. A TIME CLOCK IS REQUIRED FOR RESIDENTIAL POOLS PER |
| | SECTION 13-612.1.ABC.2.3.3 AND A POOL COVER IS REQUIRED |
| | PER SECTION 13-612.1.ABC.2.3.2. PLEASE INDICATE THESE |
| | REQUIREMENTS ON THE PLANS. |
| | |
| | 3. THE POOL PIPING SCHEMATIC DOES NOT REFLECT THE POOL |
| | PLAN. THE SCHEMATIC SHOWS SPA MAIN DRAINS AND SPA INLET |
| | BUT NO SPA IS INDICATED ON THE POOL LAYOUT. PLEASE |
| | CORRELATE. SECTION 106.1.1 |
| | |
| | 4. THE POOL PIPING SCHEMATIC DOES NOT SHOW A POOL |
| | HEATER, BUT THERE IS A POOL HEATER MANUFACTURE |
| | SPECIFICATION SHEET SUBMITTED. PLEASE CLARIFY. SECTION |
| | 106.1.1. |
| | |
| | 5. FBC-2004 424.2.6.6.2, OR FBCR-2004 |
| | SEC R4101.6.6.2 SHOW COMPLIANCE WITH |
| | ANSI/ASME A112.19.8M. PROVIDE MODEL |
| | NUMBER AND MANUF INFO FOR VAC LOCK. |
| | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES). |
| | |
| | 6. FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC. |
| | R4101.9 WATER SUPPLY, LOCAL ORD. |
| | #2853-95, BACKFLOW REQUIRED ON WATER |
| | SERVICE. (ADD TO NOTES). |
| | |
| | 7. FBC-2004 SEC. 424.2.12.1, OR |
| | FBCR-2004 SEC. R4101.12.1 PRESSURE |
| | TESTS. PER MANUFACTURE RECOMMENDATIONS, |
| | NO AIR TEST SHALL BE APPROVED FOR PVC |
| | PIPE AND FITTINGS. (ADD TO NOTES). |
| | |
| | 8. FBC-2004 SEC. 424.2.13.2, OR |
| | FBCR-2004 SEC.R4101.13.2 JOINTS AND |
| | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE |
| | PRIMER REQUIRED ON PVC PIPING. (ADD TO |
| | NOTES). |
| | |
| | 9. FBC-2004 SEC. 424.2.14.2, OR |
| | FBCR-2004 SEC. R4101.14.2 WATER |
| | RETENTION, PROVIDE A POSITIVE MEANS OF |
| | RETAINING WATER IN THE HEATER WHEN PUMP |
| | IS SHUT OFF. (MANUFACTURE SHEETS |
| | REQUIRED, PLEASE SUBMIT). -- NOT SHOWN ON MANUF. |
| | SHEETS. |
| | |
| | 10. FBC-2004 SEC. 424.2.14.4, OR |
| | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, |
| | ALL WATER HEATING EQUIPMENT SHALL BE |
| | INSTALLED WITH FLANGES OR UNION |
| | CONNECTIONS ADJACENT TO THE HEATER. |
| | (ADD TO NOTES). |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |