2009-02-06 19:31:12COMMERCIAL BUILDING (MERCANTILE), BUILDING REVIEW
 CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5120) TO VERIFY IF IMPACT FEES ARE DUE FOR
 CHANGE OF USE. BRING BACK STAMPED PLANS AND COPY OF
 PAID RECEIPT IF FEES ARE DUE.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW TO COVER ALL WORK SHOWN ON PLANS. SEC. 108.3 CITY
 AMENDMENTS TO FBC 2004. REVISE VALUATION TO INCLUDE
 DEMOLITION FEES, PROFESSIONAL DESIGN FEES AND COMPLETE
 SCOPE OF WORK TO BE PERFORMED.
  
 4- SHEET TS-1:
 A) REVISE CONSTRUCTION TYPE. THIS BUILDING CAN'T BE
 TYPE VB UNPROTECTED. AREA OF WORK IS ONLY FOR ONE
 TENANT. THERE ARE MORE TENANTS ON THIS BUILDING. THIS
 CONSTRUCTION TYPE DOESN'T APPLY TO THE SIZE OF
 BUILDING. REVISE CONSTRUCTION TYPE AS REQUIRED.
  
 B) SPECIFY IF BUILDING IS SPRINKLERED OR NOT.
  
 C) PROVIDE ONLY ONE TS-1 SHEET. THERE WERE TWO
 SUBMITTED.
  
 D) UPDATE CODE INFORMATION. REFER TO 2007 REVISIONS,
 NOT 2006.
  
 E) SPECIFY IF STRUCTURAL COLUMNS ARE REQUIRED TO BE
 FIRE RATED. COORDINATE WITH ITEM #4A ABOVE AND TABLE
 601 FBC 2004.
  
 5- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. 13-4
 OF FBC 2004.
  
 6- WIND RESISTANCE CALCULATIONS FOR ROOF TOP A/C
 EQUIPMENT:
 A) UPDATE HVAC EQUIPMENT ROOF CURB DETAIL. REVISE
 FLORIDA BUILDING CODE EDITION AND SECTION REFERENCED.
 SEE FBC 2004.
  
 B) UPDATE AMENDMENTS REFERENCED ON COVER PAGE. REFER TO
 2007 REVISIONS, NOT 2006.
  
 7- SHEET A-1.2: UPDATE GENERAL DESIGN CRITERIA:
 * REFER TO 2007 REVISIONS, NOT 2006.
 ** REVISE TABLES REFERENCED FOR LIVE LOADS. SEE FBC
 2004 FOR CORRECT TABLES AND REVISE AS REQUIRED.
  
 8- SHEET A-2.2:
 A) DOOR SCHEDULE IS MISSING SPECIFICATIONS FOR DOOR
 "D".
  
 B) PROVIDE LAYOUTS, DETAILS AND SPECIFICATIONS FOR
 GENERAL SALES AREA, FITTING ROOM AND LOUNGE AREA TO
 SHOW COMPLIANCE WITH CHAPTER 11 REQUIREMENTS SEC. 11-7.
  
 C) CLEAN ROOM: PROVIDE COMPLETE WRITTEN DIMENSIONS AND
 SIZES OF DOORS TO VERIFY COMPLIANCE WITH CHAPTER 11 FBC
 2004.
  
 D) PROVIDE COMPLETE SHOP DRAWINGS FOR CLEAN ROOM. SHOP
 DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 E) SPECIFY WHAT'S THE PROPOSED USE OF SPACE BETWEEN
 FRONT STOREFRONT AND CLEAN ROOM?
  
 9- SHEET A-2.3: TENANT SEPARATION WT-5 IS ONLY FOR ONE
 HOUR FIRE SEPARATION. NEED TO PROVIDE TENANT SEPARATION
 AS REQUIRED BY TABLE 302.3.2 OF FBC 2004. REVISE AS
 REQUIRED. ALSO, IDENTIFY OCCUPANCY USE OF TENANTS ON
 BOTH SIDES OF STORE TO PROPERLY USE TABLE 302.3.2
  
 10- SHEET A-4.0 :
 A) WAS NOT SIGNED, SEALED AND DATED AS REQUIRED BY
 CHAPTER 481 FLORIDA STATUTE.
  
 B) UPDATE BUILDING CODE YEAR AND CODE SECTION CITED ON
 HVAC EQUIPMENT ROOF CURB DETAIL. SEE FBC 2004 AND
 REVISE AS REQUIRED.
  
 11- SHEET A-4.1:
 A) NAILING SCHEDULE DOESN'T APPLY TO THIS JOB.
  
 B) PROVIDE COMPLETE DETAILS AND DIMENSIONS FOR DETAILS
 "C" AND "D" TO SHOW THE 16" HIGH VOID ON LEXAN WINDOWS
 AND SHOWING COMPLIANCE WITH CHAPTER 11 FBC 2004 SEC.
 11-7.
  
 C) DETAIL "E" TO BE COORDINATED WITH ITEM #9 ABOVE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712