Plan Review Notes
Plan Review Notes For Permit 09020052
Permit Number 09020052
Review Stop B
Sequence Number 3
Notes
Date Text
2009-04-21 15:40:51BUILDING PLAN REVIEW
 PERMIT: 09020052
 ADD: 101 S FLAGLER DRIVE
 CONT: CATALFUMO
 TEL: (561)282-8265
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: BUILDING PROVISO LIST
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2-4) COMPLIED.
  
 5) 4/22/09 COMPLIED
  
 6-9) COMPLIED.
  
 10) ROOFING PROCEDURES: NOTE NO ROOFING PERMIT APPLIED
 FOR. TO BE A BUILDING PROVISO TO BE CORRECTED UNDERTHE
 ROOFING PERMIT.
  
 A) FLAT DECK: MIAMI-DADE NOA 07-1030.01 WILL REQUIRE
 ENHANCED FASTENING.
 PAGE 9
 DECK TYPE 21 STEEL, INSULATED
 DECK DESCRIPTION 18-22 GA. TYPE B, GRADEC STEEL DECK
 SYSTEM TYPE B:
 LIMITATION# 7 ENHANCED FASTENING ALOWED, RAS
 CALCULATIONS TO BE PREPARED BY EITHER A FLORIDA
 REGISTERED PROFESSIONAL ENGINEER, REGISTERED ARCHITECT
 OR REGISTERED ROOF CONSALTANT.
 MAXIMUM DESIGN PRESSURE -90 PSF WILL REQUIRE ENHANCED
 FASTENING IN ZONE 3, EXPOSURE C REQUIRING A -115.3..
 PLANS DO INDICATE A MINIMUM OF 3 3/4 INCH ROOF
 INSULATION AT ROOF DRAINS, R VALUE OF 20.4.
  
 B) METAL ROOF: FL 2007# 11269 THIS PERMIT IS UNDERTHE
 2004 FBC NOT THE 2007
 11269.3 CEE-LOCK WITH CONTINUOUS CEE-RIB CLIP
 ROOF SLOPE OF 1/2: 12 WILL REQUIRE LAP SEALENT
 1507.4.2.
 PRESSURE LIMITATION OF -82.5 ENHANCED FASTENING, ANY
 RATIONAL ANALYSIS COMPUTATIONS SHALL BE PREPARED BY A
 QUALIFIED DESIGN PROFESSIONAL. SEE END ZONE 3 AND
 -115.7, COASTAL EXPOSURE.
  
 C) ROOFING SOLAR PANELS: ADVANCED GREEN TECHNOLIGIES,
 MIAMI-DADE NOA 07-0803.01
 LIMITATION# 8 : PHOTOVOLTAIC LAMINATES MAY BE USED WITH
 ANY APPROVED ROOF COVERING NOTICE OF ACCEPTANCE LISTING
 PHOTOVOLTAIC LAMINATES AS A COMPONENT PART OF AN
 ASSEMBLY IN THE NOTICE OF ACCEPTANCE. IF PHOTOVOLTAIC
 LAMINATES IS NOT LISTED, A REQUEST MAY BE MADE TO THE
 AUTHORTY HAVING JURISDICTION (AHJ) OR THE MIAMI-DADE
 COUNTY CONTROL DEPARTMENT FOR APPROVAL PROVIDED THAT
 APPROPRIATE DOCUMENTATION IS PROVIDED TO DETAIL
 COMPATIBILITY OF THE PRODUCTS, WIND UPLIFT RESISTANCE
 AND FIRE TESTING RESULTS.
  
 11-14) COMPLIED.
  
 15) A BUILDING PROVISO CAN BE ISSUED FOR THE SUN
 CONTROL DEVISES WITH THE WIND DESIGN CRITERIA AND
 BEFORE FABRICATION AND INSTALLATION AND REVIEWED BY THE
 DESIGN TEAM BEFORE SUBMITTING TO THE BUILDING
 DEPARTMENT.
  
 16- 20) COMPLIED.
  
 21) BUILDING PROVISO: FBC BUILDING 3110.1.2 / CITY OF
 WPB CODE OF ORDINANCES SECTION 94-546. STRUCTURE IS
 LOCATED IN AN "A" FLOOD ZONE. A FLOOD ELEVATION
 CERTIFICATE WILL BE REQUIRED.
 MINIMUM SLAB ELEVATION IS 7.5' LOCATED IN A A5 FLOOD
 ZONE, NOTE ANY ELECTRICAL OR MECHANICAL SLABS FOR
 EQUIPMENT WILL NEED TO BE ABOVE THE 7.5' ELEVATION.
  
 22) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION.
 ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL
 BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT
 THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT
 TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER
 TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY
 OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL
 OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION
 ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE
 WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY
 REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY,
 DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS,
 PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ
 FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A
 PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED
 DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED ENGINEER SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL
 OF THE FINAL INSPECTION.
  
 23) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW
 CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO
 REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN
 ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND
 DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION
 SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE
 DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND
 DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH
 WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR
 SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS
 WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED
 SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN
 ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO
 VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE
 PURSUANT TO SECTION 113 OF THIS CHAPTER.
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved