| Plan Review Notes For Permit 09020012 |
| Permit Number |
09020012 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2009-03-05 13:50:37 | REVISE SHEET 1 OF 1, FBC3101. (DESIGN CRITERIA STATES | | | FABRIC TO BE REMOVED WHEN WINDS EXCEED 90 AND THE FRAME | | | IS DESIGNED TO 75 - DOES NOT COMPLY WITH MINIMUM CODE. | | | CALCULATIONS ARE FOR DESIGN TO 90MPH) | | | | | | **AT CONTRACTOR'S RISK** |
|