| Plan Review Notes For Permit 09020001 |
| Permit Number |
09020001 |
|
| Review Stop |
E |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2009-12-29 11:51:35 | | | | | | | REVISION DENIED | | | | | | THE FOLLOWING ARTICLES ARE FROM THE 2005 NEC. | | | | | | 1} 240.24 (E) NOT LOCATED IN BATHROOMS IN DWELLING | | | UNITS AND GUEST ROOMS OR GUEST SUITES OF HOTELS AND | | | MOTELS, OVERCURRENT DEVICES, OTHER THAN SUPPLEMENTARY | | | OVERCURRENT PROTECTION, SHALL NOT BE LOCATED IN | | | BATHROOMS.*** REMOVING THE WALL FROM THE DRESSING AREA | | | NOW CREATES THIS VIOLATION. | | | | | | 2} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | | PROTECTED PER 210.8(A) (1). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|