| Date |
Text |
| 2009-10-17 10:05:16 | REVIEW #: 2ND |
| | ACTION: DENIED |
| | |
| | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS |
| | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH |
| | |
| | **PREVIOUS REVIEW COMMENTS NOT ADDRESSED** |
| | |
| | BASED ON THE SCOPE OF WORK AND THE FLOOR PLAN SHOWN, |
| | THE USE OF THIS SPACE FOR CHILD CARE WOULD CONSTITUTE A |
| | CHANGE OF OCCUPANCY. A CHANGE OF OCCUPANCY IS DEFINED |
| | AS A CHANGE IN THE PURPOSE OR LEVEL OF ACTIVITY WITHIN |
| | A BUILDING THAT INVOLVES A CHANGE IN APPLICATION OF THE |
| | REQUIREMENTS OF THIS CODE IN ACCORDANCE WITH FBC-EB |
| | SECTION 202. THE PROPOSED USE WOULD BE A DAY-CARE |
| | OCCUPANCY IN ACCORDANCE WITH FBC-B SECTION 313. |
| | |
| | WHERE THE OCCUPANCY OF AN EXISTING BUILDING OR PART OF |
| | AN EXISTING BUILDING IS CHANGED SUCH THAT THE NEW |
| | OCCUPANCY IS SUBJECT TO INCREASED MECHANICAL |
| | VENTILATION REQUIREMENTS IN ACCORDANCE WITH THE FLORIDA |
| | BUILDING CODE, MECHANICAL, THE INTENT OF THE RESPECTIVE |
| | FLORIDA BUILDING CODE, MECHANICAL PROVISIONS SHALL BE |
| | COMPLIED WITH FOR THE NEW OCCUPANCY IN ACCORDANCE WITH |
| | FBC-EB 809.1. PLEASE SHOW HOW THE VENTILATION |
| | REQUIREMENTS FOR THE PROPOSED NEW OCCUPANCY ARE TO BE |
| | MET IN ACCORDANCE WITH FBC-M 403.3. |
| | |
| | AS THIS BUILDING WAS PERMITTED PRIOR TO MARCH 15, 1979, |
| | IT SHALL MEET THE REQUIREMENTS FOR RENOVATIONS IN |
| | SECTION 101.1.3 FOR THOSE COMPONENTS WHICH ARE BEING |
| | RETROFITTED OR REPLACED IN ACCORDANCE WITH FBC-B |
| | 13-101.3.1. PLEASE DEMONSTRATE COMPLIANCE WITH THESE |
| | REQUIREMENTS AS APPROPRIATE. |
| | |
| | NOTE: THE SCOPE OF WORK AS STATED ON ORIGINAL PERMIT |
| | APPLICATION HAS EXPANDED TO INCLUDE ARCHITECTURAL AND |
| | EXTERIOR WORK. PERMIT APPLICATION SHALL BE UPDATED TO |
| | REFLECT THE ENTIRE PROPOSED SCOPE OF WORK. THE STATED |
| | VALUE ON PERMIT APPLICATION SHALL ALSO BE UPDATED TO |
| | REFLECT THE ACTUAL VALUE OF THE PROPOSED WORK. |
| | |
| | NOTE: PLANS WHICH ARE PREPARED BY A DESIGN PROFESSIONAL |
| | SHALL BEAR THE ORIGINAL SIGNATRE AND SEAL OF THE DESIGN |
| | PROFESSIONAL IN ACCORDANCE WITH FBC-B 106.1. |
| | |
| | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: |
| | RONALD J. REGUEIRO |
| | 561.805.6719 |
| | [email protected] |