| 2009-02-03 11:15:01 | BUILDING PLAN REVIEW |
| | PERMIT: 09010322 |
| | ADD: 1001 23RD STREET. |
| | CONT: CITY OF WEST PALM BEACH |
| | TEL: (561)822-2068 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS. THIS INFORMATION IS |
| | REQUIRED ON THE DRAWINGS. |
| | |
| | 3) 61G15-23.002(2) FL. ADMIN. CODE. EACH SHEET OF PLANS |
| | AND PRINTS BEING FILED FOR PUBLIC RECORD SHALL BE |
| | SEALED, SIGNED AND DATED BY THE PROFESSIONAL ENGINEER |
| | IN RESPONSIBLE CHARGE. A TITLE BLOCK SHALL BE USED ON |
| | EACH SHEET CONTAINING THE PRINTED NAME, ADDRESS, AND |
| | LICENSE NUMBER OF THE ENGINEER. IF PRACTICING THROUGH A |
| | DULY AUTHORIZE ENGINEERING BUSINESS, THE NAME, ADDRESS |
| | AND CERTIFICATE OF AUTHORIZATION NUMBER SHALL BE SHOWN |
| | ON THE PLANS. (471.025 F.S. AND 471.023 F.S.). |
| | |
| | 4) 1609.6.2 WIND DESIGN PROCEDURES SHALL BE SHOW ON THE |
| | PLANS. |
| | |
| | 1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE |
| | ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. |
| | |
| | 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION1609.5. |
| | |
| | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4. |
| | |
| | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4) |
| | |
| | 5) WHAT IS THE CORRECT HEIGHT OF THE WALL? IS IT 32 |
| | INCHES AS STATED ON THE APPLICATION OR IS IT 42 INCHES |
| | AS SHOWN ON THE DRAAWINGS? CLARIFY. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | PHONE (561)805-6726 |
| | FAX (561) 805-6676 |
| | [email protected] |
| | |