Plan Review Notes
Plan Review Notes For Permit 09010187
Permit Number 09010187
Review Stop B
Sequence Number 1
Notes
Date Text
2009-01-26 15:33:52BUILDING PLAN REVIEW
 PERMIT: 09010187
 ADD: 2201 45TH ST
 CONT: MAJOR WORKING DRAWING REVIEW/ PLAN REVIEW
 TEL: (561)635-6935
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 2) SHEET A.010 THE DOOR SCHEDULE INDICATES DOOR# 242 AS
 A PAIR OF 7'-0" DOUBLE SWING DOUBLE EGRESS DOORS, SHEET
 G.001 EXIT CALCULATIONS AT 2ND FLOOR INDICATES THE
 MINIMUM CLEAR OPENING AT EXIT DOORS TO BE 44". DOOR#
 242 IS ONLY 42" WIDE WITH A CLEAR WIDTH OF 40". SECTION
 1008.1.1 WHEN THE MOVEMENT OF BEDS IS REQUIRED THE
 MINIMUM CLEAR WIDTH OF THE DOOR IS TO BE 41.5".
  
 3) A6.02 DETAIL# 1 THE FAMILY ROOM INDICATES THE USE OF
 A MICROWAVE PLEASE INDICATE COMPLIANCE WITH 11-4.27.3
 HEIGHT. THE HIGHEST OPERABLE PART OF CONTROLS,
 DISPENSERS, RECEPTACLES, AND OTHER OPERABLE EQUIPMENT
 SHALL BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES
 SPECIFIED IN SECTIONS 11-4.2.5 AND 11-4.2.6.
 11-4.2.5 FORWARD REACH.
 IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH
 TO AN OBJECT, THE MAXIMUM HIGH FORWARD REACH ALLOWED
 SHALL BE 48 INCHES (1220 MM). THE MINIMUM LOW FORWARD
 REACH IS 15 INCHES (380 MM) [SEE FIGURE 5(A)]. IF THE
 HIGH FORWARD REACH IS OVER AN OBSTRUCTION, REACH AND
 CLEARANCES SHALL BE AS SHOWN IN FIGURE 5(B).
 11-4.2.6 SIDE REACH.
 IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A
 PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH
 ALLOWED SHALL BE 54 INCHES (1370 MM) AND THE LOW SIDE
 REACH SHALL BE NO LESS THAN 9 INCHES (230 MM) ABOVE THE
 FLOOR [SEE FIGURE 6(A) AND FIGURE 6(B)]. IF THE SIDE
 REACH IS OVER AN OBSTRUCTION, THE REACH AND CLEARANCES
 SHALL BE AS SHOWN IN FIGURE 6(C).
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 MEMBER OF BOAF, THE BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA: PROTECTING LIVES AND PROPERTY SINCE 1953.
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. UNDER FLORIDA STATE STATUTE SB 80, E-MAIL
 ADDRESSES ARE PUBLIC RECORDS.WRITTEN COMMUNICATIONS TO
 OR FROM LOCAL OFFICIALS REGARDING CITY BUSINESS ARE
 PUBLIC RECORD, AVAILABLE TO THE PUBLIC UPON REQUEST.
 YOUR E-MAIL COMMUNICATIONS ARE THEREFORE SUBJECT TO
 PUBLIC DISCLOSURE.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved