Plan Review Notes
Plan Review Notes For Permit 09010077
Permit Number 09010077
Review Stop B
Sequence Number 1
Notes
Date Text
2009-01-14 10:10:59 
 BUILDING PLAN REVIEW
 PERMIT: 09010077
 ADD: 817 7TH STREET
 CONT: ORANGE SUN INC.
 TEL: (954)545-3215
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) 2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE. INDICATE THE LEVEL OF ALTERATION ON THE
 PLANS.
  
 3) THE PLANS NEED TO CLEARLY SHOW ALL AREAS WHERE THE
 WOOD SIDING WILL BE REPLACED; THE PLANS SUBMITTED SHOW
 ONE SECTION WHERE THE SIDING WILL BE REPLACED. IF MORE
 AREAS OF THE BUILDING WILL HAVE THE SIDING REPLACED,
 THEY SHALL BE INDICATED ON THE PLANS. PROVIDE A FULL
 SET OF DRAWINGS TO SHOW ALL AREAS OF PROPOSED WORK.
  
 4) THE APPLICATION STATES REMOVE AND REPLACE WINDOWS
 BUT, IT IS NOT CLEAR HOW MANY WINDOWS WILL BE REPLACED.
 THE PLANS NEED TO CLEARLY SHOW THE LOCATION AND THE
 SIZE OF EACH WINDOW TO BE REPLACED. IF THE AGGREGATE
 AREA OF THE GLAZING EXCEEDS 25 PERCENT OF THE AGGREGATE
 AREA OF THE GLAZED OPENINGS IN THE BUILDING, IMPACT
 PROTECTION SHALL BE PROVIDED FOR EACH OPENING FBC
 (EXISTING) 507.3.
  
 5) PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THE IMPACT
 PROTECTION OF THE WINDOWS. IF THE EXISTING WINDOWS
 ALREADY HAVE IMPACT PROTECTION, THIS INFORMATION SHALL
 BE SHOWN ON THE PLANS FBC (RESIDENTIAL) R301.2.1.2.
  
 6) THE NEW WINDOW HEADER DETAIL ON SHEET A1.0 SHALL BE
 CONSTRUCTED IN ACCORDANCE WITH FIGURE R602.2 (2).
 DETAIL #6 DOES NOT COMPLY WITH THIS SECTION. THE
 DRAWINGS SHALL ALSO STATE THE SPECIES AND GRADE OF WOOD
 BEING USED FOR THE FRAMING REPAIRS. THE GALVANIZED
 STEEL CHANNEL FOR THE SHUTTERS SHALL BE SECURED TO
 STRUCTURE OF THE BUILDING IN ACCORDANCE WITH THE
 PRODUCT APPROVAL.
  
 7) NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 8) (2004 FBC) 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE &
 EXTENT OF THE WORK PROPOSED & SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, AND RULES AND REGULATIONS AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 PHONE (561)805-6726
 FAX (561) 805-6676
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved