| Plan Review Notes For Permit 09010033 |
| Permit Number |
09010033 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-01-06 11:30:38 | BUILDING PLAN REVIEW | | | PERMIT: 09010033 | | | ADD: 5608 BROADWAY | | | CONT: MARK TERLEP ROOFING | | | TEL: (561)641-2228 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1-6-09 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | | | __OK_1.) A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | __OK_2.) CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY: | | | MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / AREA OF | | | EACH ROOF TYPE | | | | | | _XX_3.) FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY | | | YOU ARE USING. ALSO INDICATE WHICH FASTENER IF THE | | | OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. | | | | | | _XX_4.) FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. PER THE NOA, | | | THIS SHALL BE DONE BY ONE OF THE REGISTERED | | | PROFESSIONAL MENTIONED. | | | | | | _XX_5.) ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | | METHOD OF ATTACHMENT YOU ARE USING. | | | | | | _XX_6.) SEE PRODUCT LIMITATION #7. CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|