| Date |
Text |
| 2009-01-20 13:54:24 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. ALL INFORMATION REQUIRED BY FAC61G15-23.002 IS |
| | REQUIRED ON EACH SHEET. |
| | |
| | 2. ALL DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED |
| | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED |
| | ORIGINALS FS471. SOME SHEETS ARE NOT SIGNED, SEALED, |
| | AND DATED. |
| | |
| | 3. ON THE PLAN, SPECIFY EACH REACTION FORCE AND |
| | DIRECTION, FBC R CHAPTER 8. |
| | |
| | 4. SEE SHEET 2.2 AND THE SIMPSON CATALOG. SPEC SHEETS |
| | FOR THESE CONNECTORS STATE DO NOT INSTALL BOLTS INTO |
| | PILOT HOLES. THESE HOLES ARE PILOT HOLES USED DURING |
| | THE MANUFACTURING PROCESS. PLEASE REVISE OR ADDRESS. |
| | |
| | 5. DETAIL 2 2.2 AND OTHER DETAILS INCLUDING SIMPSON |
| | CONNECTORS, SPECIFY NAILING. |
| | |
| | 6. FBC2512.1, EXTERIOR PLASTER TO BE MINIMUM OF THREE |
| | COATS, REVISE DETAIL 2 2.2 AND ANY OTHER DETAILS OR |
| | NOTES WHICH SPECIFY PLASTER THICKNESS. |
| | |
| | 7. SHEET 6 REFERS TO TRUSS ENGINEERING, ISN???T THAT |
| | INCLUDED IN THIS PLAN? |
| | |
| | 8. DETAIL 2 2.3 STATES THAT ROOF FRAMING PLAN WILL |
| | PROVIDE DIMENSIONS AND NAILING FOR PLYWOOD. I WAS |
| | UNABLE TO LOCATE, PLEASE SPECIFY PLYWOOD DIMENSION AND |
| | NAILING PATTERN. |
| | |
| | 9. SHEET 8 STATES THIS IS AN OPEN STRUCTURE. SEE |
| | FBC1609.2, DEFINITION OF OPEN BUILDING AND REVISE OR |
| | CLARIFY. |
| | |
| | 10. IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE |
| | PLANS MUST BE STAMPED AND THE RECEIPT ATTACHED TO THE |
| | APPLICATION. 561-233-5025 FOR MORE INFORMATION. |
| | |
| | 11. PROVIDE WINDOW AND DOOR PRODUCT APPROVALS. IF THE |
| | NON IMPACT GLAZING IS USED, PROVIDE PRODUCT APPROVAL |
| | FOR IMPACT PROTECTION. FAC9B72 |
| | |
| | 12. IF SHUTTERS ARE USED, COMPLETE THE ATTACHED |
| | INSTALLATION SCHEDULE. ALTERNATIVELY, THIS CAN BE |
| | PROVIDED ON A SEPARATE PERMIT FOR SHUTTERS. HTTP://WWW. |
| | CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATIO |
| | N.PDF |
| | |
| | 13. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF |
| | RECORD, FBC*106.3.3. |
| | |
| | |