| | BUILDING PLAN REVIEW |
| | PERMIT: 08070556 |
| | ADD: 951 33RD STREET |
| | CONT: HORIZON ROOFING INC. |
| | TEL: (561)842-6120 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 12-29-08 |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY |
| | |
| | _OK___ 1.) A NOTICE OF COMMENCEMENT MUST BE FILED WITH |
| | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. |
| | |
| | _OK___ 2.) CONTRACTOR IS TO PROVIDE THE FOLLOWING |
| | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY: |
| | MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / AREA OF |
| | EACH ROOF TYPE |
| | |
| | __XX__ 3.) FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED IN ADDITION TO THE EVALUATION REPORT |
| | SUBMITTED, FAC9B72. WWW.FLORIDABUILDING.ORG. THE |
| | PRODUCT APPROVAL FOR THE RIDGE VENT IS EXPIRED. THE |
| | PRODUCT APPROVAL FOR THE FLAT ROOF CONTAINS TWO PAGES. |
| | THE PAGES REFERENCING ALL MATERIALS ALONG WITH CHOSEN |
| | ASSEMBLY AND THE LAST PAGE SHOWING THE GENERAL |
| | LIMITATIONS SHALL BE SUBMITTED. |
| | |
| | _XX___ 4.) FOR THE FLAT DECK, SELECT THE APPROVED |
| | ASSEMBLY YOU ARE USING. ALSO INDICATE WHICH FASTENER IF |
| | THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. |
| | |
| | _XX___ 5.) FOR THE FLAT DECK, SPECIFY THE ENHANCED |
| | FASTENING FOR CORNER AND PERIMETER ZONES. PROVIDE THE |
| | CALCULATION TO MEET -89PSF. |
| | |
| | _XX___ 6.) SEE PRODUCT LIMITATION #7. CALCULATIONS |
| | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF |
| | CONSULTANT REQUIRED FOR ENHANCED FASTENING. IF STATED |
| | IN LIMITATION #7 |
| | |
| | |