Plan Review Notes
Plan Review Notes For Permit 08120508
Permit Number 08120508
Review Stop P
Sequence Number 1
Notes
Date Text
2009-01-13 10:02:17DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 FUEL GAS
 FBC-2004 EXISTING BUILDING
 FBC-2004 RESIDENTIAL
 FBC-2004 CHAPTER 1
  
 1. SHTS 2.1 & 3.1. THE PROPOSED FLOOR PLAN SHOWS THE
 WASH MACHINE, BUT THE DEMO SHEET SHOWS NO EXISTING WASH
 MACHINE CONNECTIONS TO THE SANITARY. PLEASE INDICATE
 THE LOCATION OF THE EXISTING WASH MACHINE TO DETERMINE
 IF THE SANITARY HAS BEEN DEMO'D ACCORDING TO SECTION
 704.5. SECTION 106.1.2..
  
 2. SHT 2.1 DEMO NOTE NUMBER 8. A GAS PERMIT IS REQUIRED
 FOR THE GAS DEMO WORK. PLEASE INDICATE THE LOCATION OF
 THE GAS PIPING WORK ON THE EXISTING FLOOR PLAN DEMO.
 SECTION 106.1.2.
  
 3. SHT 3.1. A WATER HEATER IS REQUIRED. SECTION 607.1.
 SHOW THE LOCATION OF THE WATER HEATER ON THE FLOOR
 PLAN. SECTION 106.1.2.
  
 4. SHT 6.1 DETAIL 3/6.1 SANITARY RISER DIAGRAM. THE
 BRANCH LINE TO THE WASH MACHINE IS REQUIRED TO BE 3"
 PER SECTION 406.3. PLEASE INDICATE PIPE SIZE ON RISER
 DIAGRAM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  