| Permit Number |
08120457 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-01-08 14:10:42 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | | | | 1. SHT PO.1 DOMESTIC WATER ISOMETRIC SHOWS THE | | | DISHWASHER SUPPLY AS COLD WATER. PER SECTION 607.1 HOT | | | WATER SHALL BE SUPPLIED TO ALL PLUMBING FIXTURES & | | | EQUIPMENT UTILIZED FOR WASHING, CULINARY PURPOSES, & | | | CLEANSING. | | | | | | 2. SHT P0.1 DOMESTIC WATER ISOMETRIC WILL BE REQUIRED | | | TO SHOW A WATER HAMMER ARRESTOR FOR THE DISHWASHER. | | | SECTION 604.9. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|