2009-06-10 11:27:10NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW THIRD
 CHECKLIST.
 REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007
 REVISIONS.
  
 ***NOTE: ONLY ONE SET OF ENGINEER'S PLANS WERE
 SUBMITTED THIS TIME.
  
 1- PLANS TO SPECIFY ALL LIVE AND DEAD LOADS AS REQUIRED
 BY SEC. R301.1 AND TABLE R301.5 OF 2004 FLORIDA
 RESIDENTIAL CODE. NOTE: ATTIC LIVE LOADS NEED TO BE
 INCLUDED ALSO. (REPEAT COMMENT- THREE TIMES).
 STRUCTURAL LOADS SPECIFICATIONS SUBMITTED ON SHEET A3
 ARE VERY CONFUSING AND STILL ARE NOT ADDRESSING THE
 REQUIRED ATTIC LIVE LOADS REQUIRED BY TABLE R301.5 OF
 2004 FLORIDA RESIDENTIAL CODE. (THIS IS THE THIRD TIME
 THAT THIS ISSUE IS NOT ADDRESSED. ENGINEER TO PAY FOUR
 TIMES THE FEE FOR PLAN REVIEW AS REQUIRED BY FLORIDA
 STATUTE SEC. 553.80(2)(B). SEE ATTACHED COPY. ENGINEER
 OWES $3,705.63 FOR MULTIPLE PLAN REVIEW REJECTIONS).
  
 2- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) ENTRY DOOR AND KITCHEN AND BEDROOM EXTERIOR DOORS.
 ACCORDING TO MIAMI-DADE COUNTY WEBSITE NOA 07-0731.04
 SUBMITTED IS NO GOOD. FILE FOR THIS NOA WAS CLOSED BY
 MIAMI-DADE COUNTY. SEE ATTACHED COPY FROM MIAMI-DADE
 COUNTY. PROVIDE CURRENT NOA AND ENGINEER TO REVIEW
 PRODUCT APPROVAL PRIOR TO SUBMITTAL.
  
 B) HURRICANE SHUTTERS: PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE. COMPLETE ALL THE
 INFORMATION AND CLEARLY MARK ON SHUTTERS DRAWINGS
 SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, BUILD
 OUT, ETC) AND SPECIFIC ANCHOR TYPE AND SPACING TO BE
 USED. (REPEAT COMMENT- THREE TIMES).
 THIS ITEM WAS NOT ADDRESSED AT ALL. PROVIDE COMPLETE
 INFORMATION.
  
 3- SINCE THE ENERGY CALCULATIONS ARE TAKEN THE CEILING
 FAN CREDIT, THEN THE ELECTRICAL PLAN NEEDS TO SHOW SIZE
 OF CEILING FANS AS REQUIRED BY TABLE 13-607.1.A.1 OF
 FBC 2004. AND, THEY NEED TO BE INSTALLED FOR
 INSPECTION. NEED TO REVISE SIZE OF CEILING FAN ON
 LIVING ROOM.
 REPEAT COMMENT. SIZE WAS NOT CHANGED
  
 4- PROVIDE DRAINAGE PLAN TO SHOW COMPLIANCE WITH SEC.
 R401.3 OF 2004 FLORIDA RESIDENTIAL CODE.
 REVISE DRAINAGE PLAN SHOWN ON SITE PLAN ON SHEET A1.
 ARROWS SHOW WATER TO BE DIVERTED TO THE ADJACENT
 NEIGHBORS. WATER CAN'T RUN INTO ADJACENT PROPERTIES.
 (REPEAT COMMENT).
  
 5- SHEET A1:
 A) SPECIFY ATTIC SIZE TO SHOW COMPLIANCE WITH SEC. R807
 OF 2004 FLORIDA RESIDENTIAL CODE.
 22" X 22" SIZE SHOWN DOESN'T COMPLY. REVISE AS
 REQUIRED. (REPEAT COMMENT).
  
 B) COORDINATE DESIGN PRESSURES FOR WINDOWS. INFORMATION
 SHOWN ON THE OPENINGS ON BUILDING INFORMATION CHART
 DOESN'T MATCH INFORMATION SHOWN ON EXTERIOR ELEVATIONS.
 REVISE AS REQUIRED TO MATCH. (REPEAT COMMENT).
  
 C) ENTRY DOOR TO BE MIN. 3'-0" WIDE BY 6'-8" HEIGHT AS
 REQUIRED BY SEC. R311.4.2 OF 2004 FLORIDA RESIDENTIAL
 CODE.
 FOUNDATION PLAN SHOWS ENTRY DOOR OPENING TO BE 3'-2" .
 THIS MASONRY OPENING WON'T ALLOW TO INSTALL 3'-0" WIDE
 DOOR. REVISE AS REQUIRED. NOTE: KEEP IN MIND REQUIRED
 BUCK SIZE. SEE PRODUCT APPROVAL. (REPEAT COMMENT).
  
 D) MASTER BATHROOM TYPE OF DOOR SHOWN ON FLOOR PLAN
 DOESN'T MATCH TYPE OF DOOR SHOWN ON DOOR SCHEDULE.
 REVISE AS REQUIRED.
 NOT ADDRESSED. (REPEAT COMMENT).
  
 E) SIZE OF WINDOW SPECIFIED ON WINDOW SCHEDULE DOESN'T
 MATCH SIZE OF WINDOW SHOWN ON BUILDING INFORMATION
 CHART. REVISE AS REQUIRED.
 NOT ADDRESSED. WINDOW SCHEDULE SHOWS H32, WHILE
 BUILDING INFORMATION CHART SHOWS H33. REVISE AS
 REQUIRED TO MATCH. (REPEAT COMMENT).
  
 F) NOTE INSIDE FOUNDATION PLAN CALLS FOR 48" MAX.
 SPACING FOR VERTICAL REINFORCEMENT BETWEEN FILLED
 CELLS. FOUNDATION PLAN AND FLOOR PLANS SHOW SOME AREAS
 WHERE THE THE MAX. VERTICAL SPACING OF FILLED CELLS
 EXCEED THE 48". REVISE AS REQUIRED.
 PLANS NOW DON'T SPECIFY THE SPACING OF VERTICAL
 REINFORCEMENT. PROVIDE SPECIFICATIONS OR PROVIDE
 DIMENSIONS ON FOUNDATION PLAN. (REPEAT COMMENT).
  
 G) REVISE BUILDING WIDTH AND BUILDING LENGTH DIMENSIONS
 SHOWN ON BUILDING INFORMATION CHART. SEE FLOOR PLANS
 FOR ACTUAL DIMENSIONS.
 REVISE BUILDING LENGTH. (REPEAT COMMENT).
  
 H) REVISE BUILDING SIDE SETBACK DIMENSIONS SHOWN ON
 SITE PLAN. 122'? (REPEAT COMMENT).
  
 6- SHEET A2:
 A) WHERE IS BEAM B-2 SPECIFIED ON EXTERIOR CMU WALL
 SECTION A/A2?. (REPEAT COMMENT).
  
 7- SHEET A3:
 A) REVISE NUMBER/SIZE OF NAILS AND UPLIFT LOADS SHOWN
 ON TRUSS CONNECTORS SPECIFIED ON ROOF FRAMING PLAN. SEE
 CONNECTOR PRODUCT APPROVAL AND REVISE AS REQUIRED.
 NOT ADDRESSED. (REPEAT COMMENT).
  
 B) REVISE SIZE OF STRUCTURAL BUCK SHOWN ON BUCK DETAIL
 FOR DOOR. SEE PRODUCT APPROVAL FOR REQUIRED SIZE. ALSO,
 DOOR FRAME NEEDS TO BE FULLY SUPPORTED ON BUCK AS
 REQUIRED BY SEC. R613.6 OF 2004 FLORIDA RESIDENTIAL
 CODE. PROVIDE BUCK SIZE THAT PROVIDES FULL SUPPORT TO
 DOOR FRAME. (REPEAT COMMENT).
  