| Date |
Text |
| 2008-12-24 15:45:56 | BUILDING PLAN REVIEW |
| | PERMIT: 08120274 |
| | ADD: 303 BANYAN / 4TH FLOOR |
| | CONT: LCI CONSTRUCTION |
| | TEL: (561)578-5930 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 1B)INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, |
| | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: |
| | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS |
| | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & |
| | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 SUPPLEMENTS AND 2004 EXISTING |
| | BUILDING CODE WITH 2007 SUPPLEMENTS. |
| | |
| | 2) ENERGY CODE , THE PROJECT SUMMARY INDICATES WHOLE |
| | METHOD "A" WAS SUBMITTED WHOLE BUILDING PERFORMANCE |
| | METHOD, THIS IS A 4TH FLOOR TENANT BUILD-OUT NOT A |
| | WHOLE BUILDING. PLEASE REVIEW 13-101.1.3. RENOVATIONS |
| | AND 13-202 DEFINITION FOR RENOVATIONS. BY DEFINTION |
| | THIS IS NOT A RENOVATION.SEE 13-400.0.C.4. EXISTING |
| | BUILDINGS NOT MEETING THE DEFINTION OFA RENOVATION IN |
| | WHICH NEW HEATING,COOLING,WATER HEATING, ELECTRICAL OR |
| | LIGHTING SYSTEMS ARE INSTALLED SHALL MEET THE BASIC |
| | PRESCRIPTIVE MINIMUM EFFICIENCIES LISTED IN THE CODE |
| | FOR THE SYSTEMS BEING CHANGED. |
| | |
| | 3) SHEET A1.1: |
| | |
| | 3A) DOOR# 45& 6, BOTH ARE INDICATED AS A 2'-6" DOOR ON |
| | THE DOOR SCHEDULE, 11-4.13.5 MINIMUM CLEAR OPENING IS |
| | 32" , OPENINGS MORE THAN 24 INCHES IN DEPTH SHALL |
| | COMPLY WITH SECTIONS 11-4.2.1 AND 11-4.3.3. |
| | 3B) DOOR# 42 REQUIRES 1'-6" CLEAR ON THE PULL SIDE, |
| | PLEASE REVIEW 11-4.13.6. MANEUVERING CLEARENCES AT |
| | DOORS. |
| | |
| | 3C) ROOM # 127 THE EMPLOYEE LOUNGE INDICATES A SIDE |
| | APPROACH, AND SHEET A4.1 DETAIL# 4 ALSO INDICATE DOORS |
| | ON THE FRONT MAKING IT IMPOSSIBLE FOR A FRONT APPROACH. |
| | 11-4.24.2 HEIGHT. SINKS SHALL BE MOUNTED WITH THE |
| | COUNTER OR RIM NO HIGHER THAN 34" ABOVE THE FINISH |
| | FLOOR. |
| | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" |
| | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS |
| | 11-4.2.4 SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW |
| | FORWARD APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN |
| | ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 |
| | INCHES (485 MM) UNDERNEATH THE SINK. |
| | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT |
| | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) |
| | COMPLYING WITH SECTION |
| | |
| | 4) SHEET A3.1 HAS VARIOUS DETAILS INDICATING SOFFITS |
| | HUNG FROM STRUCTURE ABOVE, PLEASE PROVIDE WHAT TYPE OF |
| | ATTACHMENT METHOD WILL BE USED. 106.1.2 ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 5) SHEET A3.1 DETAIL# 14 INDICATES A FIRESTOPPING AT |
| | THE 4TH FLOOR MEZZANINE LEVEL, ITHERE ARE NO PLANS OR |
| | DETAILS FOR WORK TO BE COMPLETED ON THAT LEVEL, OR PART |
| | OF THIS PERMIT? |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |