| Notes |
| Date |
Text |
| 2008-12-12 10:32:32 | 2004 FBC W/2007 REVISIONS | | | RECOVER ROOF | | | | | | DENIED BY BUILDING | | | | | | 1) THE PROJECT STRUCTURE IS LOCATED ADJACENT TO A LAKE | | | AND IS CONSIDERED EXPOSURE C. FBC 1609.4 | | | | | | 2) SUBMIT SIGNED AND SEALED RAS 117 CALCULATIONS FROM | | | THE ENGINEER. SEE LIMITATION #7 OF THE NOA AND RULE | | | 9B-72. | | | | | | 3) THE FASTENER SPACINGS ON THE LETTER FROM THE | | | ENGINEER ARE INCORRECT EVEN FOR EXPOSURE CATEGORY B. | | | PLEASE CORRECT. | | | | | | 4) NOTE: ONE COPY OF THE ENGINEER'S LETTER HAS BEEN | | | RETAINED BY THIS OFFICE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|