| 2009-02-27 17:24:40 | RESIDENTIAL (R3) ADDITION/ALTERATION, BUILDING REVIEW |
| | SECOND CHECKLIST. |
| | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE WITH 2007 |
| | REVISIONS. |
| | |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY |
| | SEC. 713.13 FLORIDA STATUTE. |
| | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK |
| | UP. |
| | |
| | 2- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY |
| | DCA RULE 9B-72 FOR: |
| | A) FLAT ROOF ASSEMBLY TO BE INSTALLED. |
| | ***NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL SPECIFIC |
| | APPROVED ASSEMBLY TO BE USED AND SPECIFIC BASE SHEET |
| | FASTENING OPTION. ALSO, PROVIDE RAS 117 CALCULATIONS AS |
| | REQUIRED BY GENERAL LIMITATION #7. IF THOSE |
| | CALCULATIONS ARE REQUIRED TO BE SIGNED AND SEALED, THEN |
| | PROVIDE THEM SIGNED AND SEALED. SEE GENERAL LIMITATION |
| | #7 ON LAST PAGE OF PRODUCT APPROVAL. ( NOTE: APPROVED |
| | ASSEMBLY WITH GENERAL LIMITATION #9 MAY NOT BE USED IN |
| | THIS PROJECT. CHECK THE UPLIFT PRESSURES). |
| | |
| | ***COMMENTS TO INFORMATION PROVIDED: |
| | (A) NOA 07-0111.03 SPECIFIED BY THE ENGINEER WAS NOT |
| | SUBMITTED. NEVERTHELESS, ACCORDING TO MIAMI-DADE COUNTY |
| | WEBSITE THIS NOA WAS SUPERSEDED (SEE ATTACHED COPY). |
| | NEED TO REVISE NOA AND PROVIDE ONE THAT IS CURRENT. |
| | |
| | (B) ENGINEER TO SPECIFY WHICH SPECIFIC APPROVED |
| | ASSEMBLY FROM THE NOA SUBMITTED IS GOING TO BE USED AND |
| | SPECIFY BASE SHEET FASTENING OPTION ALSO TO VERIFY |
| | COMPLIANCE WITH CALCULATED DESIGN PRESSURES (REPEAT |
| | COMMENT). |
| | |
| | (C) REVISE INFORMATION ON LETTER SUBMITTED: ADDRESS OF |
| | JOB IS NOT PALM BEACH GARDENS. REVISE NAME OF OWNER |
| | ALSO. |
| | |
| | (D) UPDATE CODE INFORMATION. REFER TO FBC 2004 WITH |
| | 2007 REVISIONS, NOT 2006. |
| | |
| | B) OK. |
| | C) OK. |
| | D) WINDOW MULLIONS. AND CLEARLY MARK ON DRAWINGS |
| | SPECIFIC MULLION SIZE AND ANCHOR TO BE USED TO VERIFY |
| | COMPLIANCE WITH PRODUCT APPROVAL AND CALCULATED DESIGN |
| | PRESSURES OF SEC. R301. |
| | |
| | ***COMMENTS TO INFORMATION PROVIDED: |
| | (A) NOA 06-1212.05 SUBMITTED EXPIRED ON JANUARY 2, |
| | 2008. NEED TO PROVIDE CURRENT ONE. |
| | |
| | (B) MULLION SIZE AND ANCHORS WERE NOT SPECIFIED (REPEAT |
| | COMMENT). |
| | |
| | E) FRENCH DOORS AS SHOWN ON PLANS. PRODUCT APPROVAL |
| | FL11146 SUBMITTED IS FOR 2007 CODE VERSION. NEED 2004 |
| | CODE VERSION. |
| | ALSO, NOA 08-0506.01 SUBMITTED IS FOR SMALL MISSILE |
| | IMPACT. NEED LARGE MISSILE IMPACT PROTECTION AS |
| | REQUIRED BY SEC. R301.2.1.2 OF 2004 FLORIDA RESIDENTIAL |
| | CODE. |
| | |
| | ***COMMENTS TO INFORMATION PROVIDED: |
| | (A) NOA 05-0729.01 SUBMITTED EXPIRED ON OCTOBER 16, |
| | 2008. NEED TO PROVIDE CURRENT ONE. |
| | |
| | (B) NEED TO PROVIDE PRODUCT APPROVAL FOR FRENCH DOORS |
| | WITH SIDELITES AS SHOWN ON PLANS. NONE SUBMITTED AT |
| | THIS TIME. |
| | |
| | F) OK. |
| | |
| | G) SINGLE HUNG WINDOWS. FL11633 SUBMITTED IS FOR 2007 |
| | CODE VERSION. NEED TO PROVIDE 2004 CODE VERSION. |
| | ALSO, NOA 08-0527.14 SUBMITTED IS FOR SMALL MISSILE |
| | IMPACT. NEED TO PROVIDE ONE FOR LARGE MISSILE IMPACT AS |
| | REQUIRED BY SEC. R301.2.1.2 OF 2004 FLORIDA RESIDENTIAL |
| | CODE. |
| | |
| | ***COMMENTS TO INFORMATION PROVIDED: |
| | (A) NOA 05-0930.03 SUBMITTED EXPIRED ON MARCH 17, 2008. |
| | NEED TO PROVIDE CURRENT ONE. |
| | |
| | 3- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT |
| | SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED |
| | BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | |
| | ***COMMENTS: |
| | THIS APPLIES TO PRODUCT APPROVALS THAT NEED TO BE |
| | RE-SUBMITTED. |
| | |
| | 4- AFTER DRAWINGS ARE REVISED, BRING THEM TO HISTORIC |
| | DISTRICT PLANNER TO GET APPROVAL STAMP. |
| | |
| | ***COMMENTS: |
| | THIS APPLIES FOR ANY DRAWING THAT IS REVISED AND |
| | REQUIRES APPROVAL STAMP. |
| | |
| | 5- SPECIFY SLOPE FOR FLAT ROOF TO VERIFY COMPLIANCE |
| | WITH SEC. R905.11.1 OF 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | ***COMMENTS TO INFORMATION PROVIDED: |
| | (A) DRAWINGS SUBMITTED SHOW 1/8" PER FOOT SLOPE. MIN. |
| | SLOPE REQUIRED IS 1/4" PER FOOT. SEC. R905.11.1. REVISE |
| | SPECIFICATIONS SHOWN ON SHEET A-1, A-3 AND DT-1. |
| | |
| | 6 PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | 13-600.0 FBC 2004. |
| | ***NOTE: MAKE SURE CORRECT REVISED FORM IS USED AND ALL |
| | INFORMATION IS PROVIDED. ALSO, MAKE SURE OWNER/AGENT |
| | ALSO SIGNS AND DATES BOTTOM OF FORM. |
| | |
| | *** COMMENTS TO INFORMATION SUBMITTED: |
| | (A) REVISE NAME OF BUILDER. |
| | |
| | (B) SPECIFY LINEAR FT ON ITEM #8A. |
| | |
| | (C) MISSING INFORMATION FOR FLAT ROOF AREA ON ITEM #10. |
| | |
| | (D) IF TAKEN CREDIT FOR CEILING FANS, THEN NEED TO |
| | SPECIFY ON FLOOR PLANS SPECIFIC FAN SIZE ON EACH ROOM |
| | AS REQUIRED BY TABLE 13-607.1.A.1 FBC 2004. |
| | |
| | (E) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. |
| | |
| | (F) TOTAL GLASS AREA AND CARDINAL ORIENTATION SHOWN ON |
| | SUMMER AND WINTER CALCULATION PAGES DON'T MATCH FLOOR |
| | PLANS. |
| | ***ALSO, THEY ARE MISSING THE INFORMATION FOR THE |
| | DOORS. REVISE AS REQUIRED. |
| | |
| | (G) NEED TO PROVIDE SEPARATE CALCULATIONS FOR MAIN |
| | HOUSE AND GUEST HOUSE AS REQUIRED BY SEC. 13-101.2.5.1 |
| | OF FBC 2004. |
| | |
| | (H) ITEM #7 WILL REQUIRE LABEL ON GLASS TO VERIFY |
| | COMPLIANCE WITH SPECIFIED U-FACTOR AND SHGC FACTOR WHEN |
| | DEFAULT FACTOR IS NOT TAKEN INTO CONSIDERATION. (THIS |
| | WILL BE DONE AT TIME OF BUILDING INSPECTION). |
| | |
| | 7- OK. |
| | |
| | 8- SINGLE HUNG 24 WINDOWS SPECIFIED ON PLANS DON'T |
| | COMPLY WITH THE EGRESS REQUIREMENTS OF SEC. R310.1.2 OF |
| | 2004 FLORIDA RESIDENTIAL CODE. REVISE AS REQUIRED. |
| | |
| | ***COMMENTS TO INFORMATION SUBMITTED: |
| | (A) INFORMATION SUBMITTED DON'T PROVIDE COMPLIANCE WITH |
| | THE EGRESS REQUIREMENTS. WHAT'S "EH24" EGRESS WINDOW. |
| | PROVIDE MANUFACTURER'S CUT SHEETS SHOWING COMPLIANCE |
| | WITH THE EGRESS REQUIREMENTS. CHECK SIZE OF WINDOWS |
| | PROVIDED ON PRODUCT APPROVAL. |
| | |
| | 9- SPECIFY THE DESIGN PRESSURES FOR ALL OPENINGS AS |
| | REQUIRED BY SEC. R301 OF 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | ***COMMENTS TO INFORMATION SUBMITTED: |
| | (A) PROVIDE CALCULATIONS SHOWING HOW THE DESIGN |
| | PRESSURES WERE DETERMINED. KEEP IN MIND LOCATION OF |
| | OPENING: END OR INTERIOR ZONE. DESIGN PRESSURES |
| | PROVIDED ARE LOW COMPARED TO THE DESIGN PRESSURES SHOWN |
| | ON TABLE R301.2(2) OF 2004 FLORIDA RESIDENTIAL CODE |
| | ACCORDING TO END OR INTERIOR WALL LOCATION. REVISE |
| | INFORMATION AS REQUIRED. |
| | |
| | 10- OK. |
| | |
| | 11- SHEET A-1: |
| | A) ROOF FRAMING PLAN: *SPECIFY NEW GIRDER TO CARRY THE |
| | ROOF JOISTS. AND SPECIFY POSTS TO SUPPORT IT AT BOTH |
| | ENDS. SEE FLOOR PLAN ON SHEET A-2 BY NEW KITCHEN AREA. |
| | IT CALLS FOR "NEW GIRDER FOR NEW 12" RAISED ROOF". |
| | ** PROVIDE DETAIL SHOWING HOW CONNECTING THE NEW ROOF |
| | JOISTS TO THE NEW GIRDER. CONNECTOR B1 IS A STRAP. NEED |
| | TO PROVIDE JOIST HANGER. SEE COMMENTS ON PLANS. |
| | |
| | *** COMMENTS TO INFORMATION SUBMITTED: |
| | (A) SIZE OF GIRDER TO CARRY THE ROOF JOIST IS STILL NOT |
| | PROVIDED. |
| | |
| | B) OK. |
| | |
| | C) REVISE ROOF FRAMING NOTES. ROOF FRAMING PLAN DOESN'T |
| | SPECIFY ROOF TRUSSES. |
| | |
| | ***COMMENTS TO INFORMATION SUBMITTED: |
| | (A) NOTES NOT CHANGED. NEW FRAMING PLAN DOESN'T INCLUDE |
| | PRE-ENGINEERED TRUSSES. |
| | |
| | 12- SHEET A-2: |
| | A) OK. |
| | |
| | 13- SHEET DT-1: |
| | A) OK. |
| | |
| | B) OK. |
| | |
| | C) SECTION 5: REVISE ROOF SHEATHING NAIL SPACING. NEED |
| | TO BE 4"O.C. AT ROOF ZONE 3# AS REQUIRED BY SEC. |
| | R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL CODE. REVISE AS |
| | REQUIRED. |
| | |
| | ***COMMENTS TO INFORMATION SUBMITTED: |
| | (A) SPECIFY SIZE OF WOOD SCREWS TO VERIFY COMPLIANCE |
| | WITH UPLIFT DESIGN PRESSURES OF SEC. R301 OF 2004 |
| | FLORIDA RESIDENTIAL CODE. |
| | |
| | (B) CLARIFY WHAT'S TYPE II INSULATED DECK. IS THERE ANY |
| | ADDITIONAL INSULATION ON THE DECK BESIDES THE R-19 BUTT |
| | INSULATION SHOWN. SPECIFY R-VALUE AND TYPE OF |
| | INSULATION ON THE DECK. COORDINATE WITH PRODUCT |
| | APPROVAL FOR FLAT DECK ASSEMBLY. ALSO, THIS INFORMATION |
| | NEED TO BE COORDINATED WITH THE ENERGY CALCULATIONS. |
| | |
| | D) OK. |
| | |
| | E) OK. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |