| Date |
Text |
| 2008-12-12 16:49:42 | BUILDING PLAN REVIEW |
| | PERMIT: 08120230 |
| | ADD: 500 BANYAN BLVD (RETAIL SPACE) |
| | CONT: CATALFUMO CONSTRUCTION LTD. |
| | TEL: (561)253-2580 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST |
| | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO |
| | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. THIS |
| | INFORMATION SHALL BE SHOWN ON THE PLANS. |
| | |
| | 4) THE DRAWINGS FAIL TO INDICATE THE TYPE OF BUILDING |
| | PER CHAPTER 6, THE USE AND OCCUPANCY PER CHAPTER 3 AND |
| | TABLE 503. |
| | |
| | 5) SHEET A1 SHOWS ONE OPEN SPACE FOR THE RETAIL STORE. |
| | THE OCCUPANT LOAD OF THE SPACE REQUIRES TWO EXITS. FBC |
| | 1014.2.1 (EXCEPTION #2) THE SEPARATION DISTANCE OF THE |
| | EXIT DOORS OR EXIT ACCESS DOORS SHALL NOT BE LESS THAN |
| | ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL |
| | DIMENSION OF THE AREA SERVED. THE LOCATION OF THE DOORS |
| | DOES NOT MEET THE REQUIREMENT. SHOW COMPLIANCE. |
| | |
| | 6) THE ORIGINAL PERMIT SHEET A1.1 REVISION #6 DATED |
| | 9-16-08 SHOWS TWO SEPARATE RETAIL SPACES AT THE SAME |
| | LOCATION. THE DOORS WERE IN COMPLIANCE WITH THE TENANT |
| | SEPARATION WALL FOR SPACE #1.101 AND SPACE #1.102. THE |
| | PLANS SUBMITTED DO NOT MATCH THE PERMIT SET; THE |
| | SEPARATION WALL IS REMOVED, INDICATING ONE TENANT. A |
| | REVISION OF SHEET A1.1 SHALL BE SUBMITTED FOR THE |
| | ORIGINAL PERMIT SET INDICATING THE REMOVAL OF THE WALL |
| | WHICH ONCE SEPARATED THE TWO TENANTS. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |