| 2008-12-09 15:23:46 | DENIED |
| | REFERENCE: |
| | FBC-2004 RESIDENTIAL |
| | FBC-2004 FUEL GAS |
| | FBC-2004 EXISTING BUILDING |
| | FBC-2004 CHAPTER 1 |
| | |
| | 1. SHT A-1 ADDRESS IN THE TITLE BLOCK DOES NOT REFLECT |
| | THE ADDRESS ON THE APPLICATION NOR THE ADDRESS ON THE |
| | OTHER SHEETS. SECTION 106.1.1. |
| | |
| | 2. SHT A-1 THE LEVEL OF ALTERATION IS INCORRECT. |
| | SECTION 303.4. |
| | |
| | 3. SHT A-1 DETAIL FOR THE SHOWER IS TITLED "DEMOLITION" |
| | PLEASE CLARIFY. SECTION 106.1.1. |
| | |
| | 4. SHT A-1 DEMOLITION PLAN. IN THE REMOVAL OF ANY PART |
| | OF A DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. |
| | PLEASE INDICATE ON THE RISER DIAGRAM WHERE THE WASH |
| | MACHINE CONNECTION TO THE SANITARY IS CAPPED. OFF |
| | SECTION 704.5. |
| | |
| | 5. SHT PE.1 THE SANITARY RISER DIAGRAM SUBMITTED IS FOR |
| | THE KITCHEN AND ANOTHER SINK NOT INDICATED ON THE FLOOR |
| | PLAN. WORK IN THE KITCHEN AREA IS NOT INDICATED ON THE |
| | APPLICATION. PLEASE SUBMIT A SANITARY RISER DIAGRAM FOR |
| | THE BATHROOM AND THE LAUNDRY ROOM SHOWING ALL PIPE |
| | SIZES, TRAPS, VENTS AND CONNECTION LOCATION TO EXISTING |
| | BUILDING DRAIN. SECTION 106.3.5.1.3(4)(6)(13). |
| | |
| | 6. A SEPARATE GAS PERMIT IS REQUIRED FOR THE GAS WATER |
| | HEATER. SEE ATTACHED SHEET WITH REQUIREMENTS FOR A GAS |
| | PERMIT. INFORMATION REQUIRED WHEN APPLYING FOR GAS |
| | PERMIT. |
| | |
| | 7. SHT S.1 HAS INFORMATION THAT IS DIFFERENT FOR EACH |
| | SHEET SUBMITTED. PLEASE SUBMIT 2 SETS OF PLANS WITH THE |
| | SAME INFORMATION FOR REVIEW. SECTION 106.1. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |